Heavy-Duty VFD Cooling Fan with Snap-On Filter Screen: Engine-Grade Pure Copper Motor, High-CFM Centrifugal Airflow, and IP54 Dust Protection for Frequency Converter Cabinets and Industrial Enclosures.
High-Performance Cabinet Filter Fan for Industrial Inverters: Precision Ball Bearings, Low Noise Operation, and Integrated Panel Fan Filter to Prevent Thermal Trips and Extend IGBT Lifespan.
Industrial Enclosure Cooling Fan & Electrical Panel Fan Filter System: Powerful Outer Rotor Motor with Tool-Free Washable Filter Screen for Dust, Moisture, and Grease Protection in Factory Cabinets.
Factory-Direct Frequency Converter Cooling Fan with Filter Screen: Pure Copper Windings, Customizable Voltage Ratings, and High Static Pressure Ventilation for Automated Control Panels & VFD Drives.
What makes these units real workhorses on the factory floor is their integrated high-density filter screen. Whether you pick the high-rpm K2E250-AH38-16 SK3244.110 for 115V setups or the power-efficient 95W K2E250-AH34-06 SK3244.700 for standard 230V lines, both models trap fine dust, metal shavings, and ambient oil mist before they ever touch your drive's sensitive electronics. It’s an all-in-one thermal management upgrade that keeps cabinet temperatures low, prevents sudden thermal trips, and drastically extends the working life of your power electronics.



Frequency converters, soft starters, and electrical switchgear naturally churn out heavy heat during continuous daily shifts. If that thermal energy gets trapped inside the enclosure—especially alongside airborne factory debris—capacitors degrade fast and drives shut down unexpectedly. Our industrial fan line, featuring the K2E250-AH38-16 SK3244.110 (115V, pulling 2600–2800 RPM) and the K2E250-AH34-06 SK3244.700 (230V, 95W at 2550 RPM), gives automation engineers a rugged, drop-in thermal solution tailored to local power standards.
By pairing an advanced outer rotor motor with a quick-snap filter assembly, both the K2E250-AH38-16 SK3244.110 and K2E250-AH34-06 SK3244.700 pull fresh ambient air into the cabinet and flush out trapped heat pockets rapidly. The front-mounted filter media stops airborne grime, dust, and particulate mist right at the cabinet wall, keeping internal circuit boards clean, dry, and cool. Thanks to a tool-free mounting design, maintenance crews can easily clip these units onto standard panel cutouts, preventing drive thermal throttling and guaranteeing smooth, uninterrupted system automation.

Industrial operators select the Frequency Converter Cooling Fan with Filter Screen for its rugged mechanical engineering, low power consumption, and thermal reliability:
Pure Copper Outer Rotor Motor: Featuring 100% high-grade pure copper windings, the permanent magnet brushless outer rotor motor produces high rotation speeds and powerful static pressure with minimal magnetic resistance and heat build-up.
High-Density Precision Bearings: Precision-fitted bearing balls roll effortlessly under intense centrifugal force. This friction-free bearing setup handles continuous continuous high-speed rotation without mechanical chatter, yielding low vibration and whisper-quiet sound output.
Integrated Dust & Splash Filter Screen: The dense filter mat stops airborne particulate ingress, preventing dust buildup inside frequency converter heat sinks while allowing smooth, unobstructed airflow.
High-Volume Centrifugal Airflow: Specially contoured fan blades maximize cubic feet per minute (CFM) output, forcing cool air deep into cramped drive enclosures to break up localized hot spots.
Tool-Free Filter Maintenance: The snap-on filter housing allows technicians to swap out dirty filter pads rapidly during routine maintenance without shutting down cabinet power.
K2E250-AH38-16 SK3244.110
| Parameter | Value |
| Model No | K2E250-AH38-16 |
| Voltage | 115V |
| Rotation Speed | 2600-2800(rpm/min⁻¹) |
| Frequency | 50/60Hz |

| Parameter | Value |
| Model No | K2E250-AH34-06 |
| Voltage | 230V |
| Rotation Speed | 2550(rpm/min⁻¹) |
| Power | 95W |
The versatility of the Frequency Converter Cooling Fan with Filter Screen makes it an ideal fit across automated production facilities and commercial spaces:
Industrial Frequency Converter Cabinets: Dissipating heat from high-power VFDs, soft starters, and power supplies in automated factories.
Chemical Plants & Heavy Industry: Guarding sensitive control logic and drive electronics against corrosive dust, ambient moisture, and chemical particulates.
Large Office Buildings & HVAC Systems: Cooling commercial HVAC drive panels, fresh air exchange units, and central pump controller boxes.
Commercial & Hotel Kitchens: Ventilating power controllers, exhaust hood drives, and refrigeration equipment exposed to greasy air.
Warehouse Storage & Logistics: Cooling automated guided vehicle (AGV) charging stations, conveyor drive enclosures, and sorting system panels.
Tunnel & Agricultural Ventilation: Protecting electrical drive gear in dusty tunnel exhaust systems, livestock farms, and greenhouse climate setups.
When you choose the Frequency Converter Cooling Fan with Filter Screen, you secure far more than reliable cabinet ventilation—you gain a competitive supply chain partnership.
As a factory-direct provider, offers complete customization options, including specialized voltage configurations, custom wire harness lengths, and tailored filter screen densities. Every Frequency Converter Cooling Fan with Filter Screen comes backed by a full set of international qualifications, compliance certifications, and comprehensive after-sales support. With large factory warehouse stock ready for immediate dispatch, guarantees short lead times, stable wholesale pricing, and long-term durability that slashes equipment warranty claims and overall maintenance overhead.
In modern industrial automation, frequency converters rely on insulated-gate bipolar transistors (IGBTs) to switch electrical power rapidly. IGBT modules generate intense localized heat during current conversion. Operating a frequency converter at elevated temperatures significantly degrades its internal electrolytic capacitors, leading to premature capacitor leakage or catastrophic driver failure.
Standard unfiltered cooling fans blow factory floor dust straight onto the hot heat sinks of frequency converters. Dust layers act as thermal insulation blankets, trapping heat and drawing moisture that causes short circuits. The Frequency Converter Cooling Fan with Filter Screen solves both thermal and contamination risks simultaneously. By maintaining laminating airflow across cooling fins while keeping dust particles trapped on the external washable filter screen, keeps cabinet temperatures well within safe operating limits, significantly extending converter service life.
Q1: Which model should I choose for my panel?
It depends on your local control voltage:
Pick the 115V K2E250-AH38-16 (SK3244.110) if you're wiring directly to standard 115V panel lines (most common in North America). It spins up to 2,800 RPM for maximum heat removal.
Go with the 230V K2E250-AH34-06 (SK3244.700) if you're running off a 230V control transformer or global power grid. It draws a steady 95W while pushing smooth, reliable airflow.
Q2: How often do we need to clean or replace the filter pads?
In clean assembly rooms, a quick check every 3 to 6 months is plenty. In high-dust environments like textile mills, farms, or machine shops, we recommend checking them monthly. Since the cover snaps off without tools, your team can clean the mat with compressed air or water during normal walk-throughs.
Q3: Do you offer OEM modifications for large cabinet builds?
Yes! As a direct manufacturer, we frequently customize harness lengths, add quick-connect plugs, supply high-density filter media for fine particles, or apply conformal coatings to the motor windings for harsh chemical environments.
Heavy-Duty VFD Cooling Fan with Snap-On Filter Screen: Engine-Grade Pure Copper Motor, High-CFM Centrifugal Airflow, and IP54 Dust Protection for Frequency Converter Cabinets and Industrial Enclosures.