LOBISONG LBG4010 Series — 40 × 40 × 10.3 mm DC Axial Fan
The LOBISONG LBG4010 series is a compact DC axial fan built around the 40 × 40 × 10.3 mm form factor, a footprint widely used where board space is tight and forced convection is the only practical way to move heat out of an enclosure. The fan is offered in 5 V, 12 V, and 24 V DC versions, making it adaptable to USB-powered accessories, standard 12 V electronics, and 24 V industrial or 3D-printer control systems alike.
Across the series, airflow typically spans 4.85–6.66 CFM, with speed options in the 5,000–7,000 RPM range and power draw between 0.72 W and 1.44 W, depending on the voltage and speed grade selected. Static pressure reaches approximately 2.52–4.55 mm-H₂O, sufficient for pushing air through dense heatsink fins or narrow vent openings rather than simply stirring air in open space. Noise output ranges from roughly 20 dB(A) at the low-speed end to 28 dB(A) at the high-speed end, a level that remains acceptable in desktop equipment and consumer electronics but becomes noticeable in truly quiet environments.
The LBG4010 is available with sleeve bearing or ball bearing constructions. Sleeve-bearing versions are cost-effective and rated for approximately 30,000 hours at 25 °C, while ball-bearing variants extend service life to 40,000–50,000 hours and tolerate higher ambient temperatures up to 70 °C. Housings and impellers are molded from PBT UL 94V-0 flame-retardant plastic, and lead wires follow the UL 1007 26 AWG standard with red (+) and black (−) polarity marking. The fan also includes polarity protection, so reversing Vcc and GND will not destroy the circuit within a brief miswiring event.
Typical applications include 3D-printer hotend and part cooling, small power supplies, network appliances, medical instruments, and embedded control cabinets where a 40 mm opening is already defined and thermal headroom is limited. With its combination of low profile, multi-voltage availability, and bearing options spanning budget to long-life duty, the LBG4010 series fills a practical niche: it is small enough to fit almost anywhere, yet specified broadly enough to cover both intermittent consumer use and continuous industrial operation.
LBBE3G355-102PS-02 EC medium-pressure backward curved centrifugal fan, aluminum rotor, 3534m³/h at 585W for fresh air.
LBBE3G355-102NS-24 EC medium-pressure backward curved centrifugal fan, aluminum rotor, 4172m³/h at 520W for purifiers.
LBBE3G355-102NS-11 EC external rotor backward curved centrifugal fan, aluminum rotor, 5047m³/h at 700W for AC cooling.
LOBISONG LBG4015 Series — 40×40×15 mm DC Axial Fan
The LBG4015 Series is LOBISONG’s 40 mm square DC axial fan with a 15 mm frame depth, positioned for space-critical cooling in small enclosures and dense electronics. Public datasheets specific to the LBG4015 designation are not readily indexed, so the performance envelope below reflects the established 4015-class architecture this series belongs to rather than a single locked specification table.
Across the 4015 class, 5 V, 12 V, and 24 VDC inputs are standard. Speed options commonly span 4,000 RPM to 12,000 RPM, producing airflow from approximately 4.7 CFM on quiet low-speed variants up to 13–15 CFM at the high end. Maximum static pressure follows the same progression, from roughly 1.8 mmH₂O (≈17.6 Pa) at 4,000 RPM to 11.6 mmH₂O (≈114 Pa) at 10,000 RPM, with some high-speed versions reaching higher. Noise output tracks that range from the low-20s dBA on low-speed models to the low-40s dBA at maximum performance.
Construction uses a UL94V-0 thermoplastic frame and impeller, with sleeve or ball bearing options. Available functions typically include FG tachometer output, RD locked-rotor alarm, PWM speed control, reverse-polarity protection, and auto-restart, along with optional IPX5 protection for moisture-prone environments. Operating temperature spans −10°C to +70°C.
With its 40 mm footprint and 15 mm depth, the LBG4015 Series suits compact power adapters, 1U embedded systems, networking appliances, portable instruments, and small-form-factor enclosures where board space and height are both tightly constrained and targeted spot-cooling is required.
The LOBISONG LBG4020 Series is a compact 40mm x 40mm x 20mm DC axial fan engineered for space-constrained cooling applications where reliable, targeted airflow is essential. As part of LOBISONG’s line of miniature brushless cooling fans, the LBG4020 balances performance, longevity, and low-noise operation within a standardized 4020 footprint.
Key Specifications & Options
The series typically supports 5V, 12V, or 24V DC inputs, accommodating common electronics and embedded-system power rails. Bearing choices directly influence service life: sleeve bearings offer a cost-effective solution rated around 30,000 hours, hydraulic bearings extend longevity to approximately 35,000 hours with quieter operation, and dual ball bearings deliver the longest lifespan—up to 50,000 hours—making them suitable for continuous-duty deployments. Airflow and speed vary by configuration; comparable 4020 fans achieve roughly 5–9 CFM at speeds between 5,000 and 8,500 RPM, with noise levels often kept in the 20–30 dBA range depending on the chosen bearing and speed profile.
Design & Integration
The 20mm thickness provides additional static pressure capability compared with thinner 10mm fans, helping overcome resistance in dense enclosures or heatsink assemblies. Common features across the 4020 class include PWM speed control, FG tachometer output, and optional IP-rated protection for dusty or humid environments. The compact square frame integrates easily into 3D printer hotend cooling, small-form-factor PC cases, network appliances (NAS, switches), and portable electronics where board space is at a premium.
Reliability & Customization
LOBISONG supports OEM/ODM flexibility on voltage, connector type, lead length, and bearing selection, allowing the LBG4020 to be tuned for specific acoustic or durability targets. With a focus on consistent airflow delivery in a minimal footprint, the LBG4020 Series serves as a practical thermal solution for compact, heat-sensitive designs.
LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal blower, 7-blade rotor, 2235m³/h at 160W, quiet cleanroom ventilation.
LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal fan, 7-blade rotor, 2235m³/h at 160W, 70-80dB for cleanrooms.
LBBE3G310-138NT-05 EC high-power backward curved centrifugal turbine fan, aluminum rotor, 4398m³/h at 980W for purifiers.
LBBE3G310-102NS-19 EC low-pressure backward curved centrifugal fan, 7-blade rotor, 2936m³/h at 370W, 70-80dB for cleanrooms.
LBBE3G310-102NS-18 EC medium-pressure backward curved centrifugal fan, galvanized/aluminum rotor, 2884m³/h at 450W for purifiers.
LBBE3G310-102NS-19 EC low-pressure backward curved centrifugal fan, 7-blade aluminum rotor, IP44, 2850m³/h at 370W, 70-80dB cooling blower.
LBBE3G310-092PS-11 EC low-noise medium-pressure backward curved centrifugal fan, aluminum impeller, 2235m³/h at 160W, 75-78dB for clean ventilation.
LBBE3G310-092NS-22 EC medium-pressure backward curved centrifugal blower, galvanized/aluminum rotor, 2678m³/h at 175W, 73-85dB for plant cooling.
LBBE3G310-072PS-01 brushless EC backward curved centrifugal fan, aluminum impeller, 2266m³/h at 175W, 66-74dB, variable speed for factory cooling.
The LBMR4020 Series (closely related to the widely documented MR4020 platform) is a family of 40 mm × 40 mm × 20 mm DC axial fans that occupies the mid-profile position within the 40 mm fan ecosystem—thicker than ultra-slim 10 mm variants for greater thermal headroom, yet shallower than the 28 mm high-output series for tighter installations.
Bearing and construction. The series is built around a ball bearing system, a standard choice for continuous-duty applications that demand consistent performance and extended service life. The frame and impeller are molded from plastic, with each unit weighing approximately 24 g (0.053 lb), a lightweight profile suited to vibration-sensitive or weight-constrained assemblies. The series carries CE, cUL, TUV, and UL approvals, confirming compliance with major international safety and quality standards.
Performance envelope and feature options. The platform supports both 12 VDC and 24 VDC nominal inputs, with speeds spanning from 6,500 RPM to 12,000 RPM. Airflow ranges from 9.4 CFM (0.263 m³/min) on the low-speed end to 17.3 CFM (0.484 m³/min) in the highest-output configurations. Static pressure correspondingly climbs from 0.160 in H₂O (40.0 Pa) to 0.540 in H₂O (134.5 Pa) . Acoustic output remains tightly controlled across the range, from 26.5 dB(A) at 6,500 RPM to 41.0 dB(A) at 12,000 RPM.
A notable strength of the series is its feature granularity. Base models operate as simple 2-wire fans with Auto Restart protection. Mid-tier variants add Speed Sensor (Tachometer) output for RPM monitoring. Top-tier configurations incorporate both PWM speed control and tachometer feedback on a 4-wire interface, enabling closed-loop thermal regulation within the host system. All variants include locked rotor protection or auto-restart functionality to safeguard the motor against stall conditions.
Applications. The 40 × 20 mm form factor is widely deployed in compact electronic enclosures, server racks, industrial control equipment, and networking hardware where thermal management must be achieved within a slim vertical clearance. The LBMR4020 is the appropriate specification when a fixed 40 mm mounting pattern demands more airflow and pressure capability than a 10 mm fan can provide, but the installation depth cannot accommodate a 28 mm high-output model. Its combination of ball-bearing durability, flexible control options, and balanced acoustic performance makes it a pragmatic mid-tier thermal solution.
The LBMD4028 Series occupies the highest-output tier of the 4028 platform, distinguished by its focus on maximum thermal performance through elevated rotational speeds and a feature set geared toward system-level monitoring and protection. It shares the 40 mm × 40 mm × 28 mm envelope with the LBH and LBMH variants, but its specification leans decisively toward pressure head and airflow delivery.
Bearing and construction. The series employs a ball bearing system, a standard choice for continuous-duty industrial and server applications where bearing longevity under sustained high-speed operation is critical. Frame and impeller are molded from UL94V-0 rated PBT, providing flame retardancy and thermal stability. A defining characteristic of the LBMD tier is its comprehensive protection and monitoring suite: many variants incorporate PWM speed control, tachometer (speed sensor) output, locked-rotor alarm signaling, and Thermal Overload Protection (TOP). This level of integration allows the fan to participate actively in closed-loop thermal management and fault-detection architectures, rather than operating as an uncontrolled fixed-speed device.
Performance envelope. The series supports 12 VDC and 24 VDC inputs, with speeds spanning from 8,000 RPM at the lower end to 15,000 RPM and beyond in high-output configurations. Airflow covers a broad range, with representative figures including 15.2 CFM (0.426 m³/min) at 10,300 RPM and 24.3 CFM (0.680 m³/min) at the 15,000 RPM ceiling. Static pressure reaches as high as 300.4 Pa (1.206 in H₂O) on the most aggressive 15,000 RPM variants, a pressure capability that positions the LBMD as a true high-impedance solution for dense heatsinks and restricted airflow paths. Acoustic output scales with speed, from roughly 44 dBA in mid-range models to approximately 53 dBA at maximum output.
Applications. The LBMD4028 is specified where a fixed 40 mm mounting pattern must support cooling loads that approach the practical limits of the 4028 form factor. Typical deployments include high-density server power supplies, telecommunications rectifiers, industrial drives, and compact thermal chambers where the fan must overcome significant system impedance while providing speed feedback and fault signaling to the host controller. It is the appropriate choice when the design demands not merely airflow, but monitored, protected, and dynamically controllable airflow within the 40 × 28 mm envelope.
The LBH4028 Series is a 40 mm × 40 mm × 28 mm DC axial fan family that shares the 4028 form factor with the LBMH4028 but sits in a different position within the product hierarchy. While the LBMH variants emphasize advanced control features such as PWM, tachometer output, and thermal overload protection, the LBH designation points toward a more standard high-output configuration, built around a robust dual ball bearing system for durability in continuous-duty applications.
Bearing, materials, and construction. The series relies on dual ball bearings, a choice that favors resistance to wear and consistent performance over extended operating hours compared with sleeve-bearing designs. Frame and impeller are molded from PBT plastic, and the fan carries an insulation Class A rating with an operating temperature window of −10°C to 70°C. Weight is listed at approximately 40–60 g depending on the specific variant and optional features. Available function options across the 4028 platform include FG (tachometer), RD (rotation detection), PWM, and VC (voltage control), allowing the LBH4028 to be specified with or without speed monitoring depending on the application.
Performance envelope. The series supports 12 VDC and 24 VDC nominal inputs. Across the 4028 platform, speeds span from 6,000 RPM at the low end to 22,000 RPM in the highest-output configurations, with airflow reaching approximately 8.2 to 30.0 CFM (0.23–0.85 m³/min) and static pressure climbing as high as 68 mmAq (2.68 in H₂O) on the most aggressive variants. Noise scales from the low 30s dBA at 6,000 RPM to roughly 56 dBA at maximum speed. A representative 12 V variant at 18,000 RPM delivers 24.6 CFM at 45.7 mmAq and 52.8 dBA, illustrating the pressure-oriented tuning characteristic of the higher-speed LBH configurations.
Applications. The 4028 depth is particularly valued where 40 mm mounting is fixed but cooling demand exceeds slim-fan capability. Typical deployments include server PSU cooling, network and communication equipment, industrial control modules, and compact electronic enclosures where the fan must push air through dense component arrays or restricted internal pathways. The LBH4028 is the appropriate specification when a straightforward, durable ball-bearing fan is preferred over a feature-rich PWM-controlled model, while still demanding the thermal headroom that only a 28 mm-thick 40 mm fan can provide.