LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal blower, 7-blade rotor, 2235m³/h at 160W, quiet cleanroom ventilation.
Built around a 310mm seven-blade rotor, the LBBE3G310-092NS-20 is an EC brushless backward curved centrifugal blower intended for cleanroom make-up air, cabinet ventilation and heat dissipation. Its 160W EC motor turns the rotor at 1850 r/min to deliver 2235 m³/h of low-pressure airflow, with noise held between 70 and 80 dB. Sealed to IP54 or IP44 depending on variant, Class F insulated and rated S1 continuous duty from -25℃ to +60℃, the unit runs on 230V 50/60Hz. This model opens a three-branch 310mm family that also covers a 150W light-duty blower and a 360W mid-range unit, letting integrators standardize one housing across purification and cooling projects.
| Model | Power | Speed | Air Flow |
| LBBE3G310-92NS-20 | 160 W | 1850 r/min | 2235 m³/h |
| LBBE3G310-92NS-17 | 150W | 1750 r/min | 2410 m³/h |
| LBBE3G310-102NS-16 | 360W | 2149 r/min | 2869 m³/h |
Keeping noise acceptable in occupied cleanrooms and support zones is a primary requirement, and this backward curved centrifugal fan is tuned around that constraint. The seven-blade rotor spreads each airflow pulse across more blade passes, avoiding the harsh discrete whine produced by fewer, heavier blades, while the 1850 r/min running speed keeps tip velocity moderate. The result is a 70–80 dB operating band that pairs acceptably with enclosure or duct attenuation, and speed trimming can lower the unit further during light occupancy when quiet running matters most.
For cleanroom and purifier applications, resistance comes mainly from pre-filters, panel grilles and short duct runs rather than long high-pressure risers. This backward curved centrifugal fan is built as a low-pressure blower, moving 2235 m³/h against that light-to-moderate resistance without oversizing the motor. The backward-inclined blade profile keeps airflow stable as filters gradually load, and the 310mm rotor delivers a broad, even airflow plume that distributes across the room or cabinet rather than concentrating on one spot.
The 160W drive core is a brushless EC motor with no brushes to wear or replace, which removes one of the common failure points in continuously running ventilation equipment. The controller maintains good efficiency at reduced speed, so the blower can follow actual temperature or occupancy instead of being throttled by a damper that discards fan energy as pressure loss. Soft-start current ramp protects supply circuits at switch-on, and sealed ball bearings mean the routine service list stays limited to inspection rather than relubrication.




Two enclosure grades cover the common installation styles. IP54 protects against particles above 1mm and splashing water in plant rooms and semi-protected interiors; IP44 suits enclosed purifier cabinets, ceiling plena and ducted positions behind panels. The sealed housing keeps dust and incidental moisture away from the Class F windings and bearing, preserving airflow consistency over daily use where an open-frame motor would accumulate grit and gradually lose output.
The NS-20, NS-17 and NS-16 models keep the same 310mm impeller envelope, so the duct collar, mounting holes and housing dimensions can be held constant while output varies by project. The 160W NS-20 and 150W NS-17 cover light purification and cooling duty; the 360W NS-16 handles mid-range airflow in larger cabinets or rooms. Every variant uses sealed ball bearings, S1 duty and the same insulation and temperature rating, and carries ISO, BSCI, ETL, CE, EMC, RoHS and GS certification, with OEM/ODM options available for bulk orders.


Q: How much air does the NS-20 move? A: This backward curved centrifugal fan delivers 2235 m³/h at 1850 r/min on 160W, a low-pressure rating for standard cleanroom ventilation and equipment cooling with light duct or filter resistance.
Q: Can the fan run continuously and be speed-adjusted? A: Yes. S1 continuous duty and sealed ball bearings support non-stop running, and the EC motor allows stepless speed adjustment to match airflow and noise to the actual room load.
Q: What other outputs share this frame? A: The NS-17 provides 2410 m³/h at 150W, and the NS-16 provides 2869 m³/h at 360W. All three use the same 310mm rotor platform and protection, insulation and temperature ratings.
LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal blower, 7-blade rotor, 2235m³/h at 160W, quiet cleanroom ventilation.