LBBE3G310-072PS-01 brushless EC backward curved centrifugal fan, aluminum impeller, 2266m³/h at 175W, 66-74dB, variable speed for factory cooling.
The LBBE3G310-072PS-01 is a 310mm EC backward curved centrifugal fan designed for factory workshop heat dissipation, ventilation and general exhaust. Built with an aluminum alloy impeller and a brushless DC EC motor, this backward curved centrifugal fan delivers 2266 m³/h at 1810 r/min on 175W shaft power, classified as a medium-pressure unit with outlet noise held between 66 and 74 dB. The assembly carries IP55/IP54/IP44 sealing options, Class F insulation, S1 continuous duty and a -25℃ to +6 0℃ ambient range, supplied for 230V/115V 50/60Hz. As the entry model of this five-variant 310mm PS/PT family, this backward curved centrifugal fan covers standard plant cooling, while the other four variants scale from 360W up to 980W and airflow to 4398 m³/h for fire smoke exhaust, factory exhaust and kitchen extraction.
| Model | Power | Speed | Air Flow |
| LBBE3G310-072PS-01 | 175W | 1810 r/min | 2266 m³/h |
| LBBE3G310-102PS-02 | 360W | 2149 r/min | 2869 m³/h |
| LBBE3G310-102PS-03 | 700W | 2960 r/min | 4120 m³/h |
| LBBE3G310-138PT-04 | 980W | 2600 r/min | 4398 m³/h |
| LBBE3G310-072PS-06 | 175W | 1710 r/min | 2266 m³/h |
This backward curved centrifugal fan uses a 310mm aluminum alloy impeller, a larger rotor that reaches rated airflow at a lower tip speed than a small high-speed wheel. The backward-inclined blade path converts motor rotation into static pressure rather than free velocity, so this backward curved centrifugal fan keeps 2266 m³/h moving against duct elbows and equipment filters instead of losing throughput once resistance rises. The larger impeller and balanced aluminum rotor also help hold outlet noise at 66–74 dB, lower than comparable small-wheel blowers running at higher rpm. The metal rotor resists heat distortion and abrasive factory dust, and its rotating mass damps vibration transmitted to the housing and adjacent structure.
The power core of this backward curved centrifugal fan is a brushless DC EC motor rated at 175W, driven by an electronically commutated controller that supports stepless variable speed regulation. The EC drive keeps efficiency high across the operating range, so this backward curved centrifugal fan can be slowed during light-load shifts instead of throttled with a damper that wastes energy as pressure loss. Speed trimming also lets the unit run quieter when the workshop is lightly occupied, and ramp-up soft start protects upstream circuits from startup surge. Because there are no brushes to wear, the motor needs no commutator maintenance over its service life.






This family is offered in IP55, IP54 and IP44 protection grades, so the exhaust centrifugal blower can be matched to its mounting zone rather than over-sealed. IP55 blocks fine dust and resists water splashing for dusty production floors and semi-outdoor plant rooms; IP54 gives dust protection for standard indoor installations; IP44 suits protected cabinet and ducted positions where only coarse dust and light splash are expected. The sealed motor housing keeps particulate away from windings and ball bearings, so this backward curved centrifugal fan holds performance steady where an open-frame blower would collect grit and drift in output over time.
Class F winding insulation gives this backward curved centrifugal fan thermal reserve for sustained full-load operation, which matters when the motor sits inside a ventilation plenum or equipment enclosure that traps its own heat. The rated -25℃ to +60℃ ambient range covers cold unheated workshops, warm summer production floors and seasonal plant-room swings without derating. S1 duty confirms this backward curved centrifugal fan is built for non-stop continuous operation rather than intermittent short bursts, and the 230V/115V 50/60Hz supply matches two common commercial grids, keeping one model compatible across export markets without a separate motor variant.
All five models in this family keep a 3 kg frame and 310mm impeller envelope, so one duct collar and mounting interface can serve every power level. The 072PS-01 backward curved centrifugal fan at 175W and 2266 m³/h covers standard workshop cooling; the 072PS-06 at 175W and 2266 m³/h serves lighter factory exhaust; the 102PS-02 at 360W and 2869 m³/h handles fire smoke exhaust systems; the 102PS-03 at 700W and 4120 m³/h covers heavy factory exhaust; the 138PT-04 at 980W and 4398 m³/h tops the range for kitchen fume extraction. Sealed ball bearings run maintenance-free, every unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, and the factory accepts OEM/ODM customization for bulk ventilation projects.




Q: What airflow does the 072PS-01 deliver? A: This backward curved centrifugal fan delivers 2266 m³/h at 1810 r/min with 175W shaft power, classified as a medium-pressure fan suited to standard factory cooling and ducted ventilation with moderate resistance.
Q: How loud is the unit and can speed be adjusted? A: The noise level is specified at 66–74 dB, and the brushless EC motor supports stepless variable speed regulation, so the backward curved centrifugal fan can be trimmed to a quieter, lower-power running point during light-load periods.
Q: Which family variant should I compare for heavier exhaust? A: The 102PS-02 gives 2869 m³/h at 360W for fire smoke exhaust; the 102PS-03 gives 4120 m³/h at 700W for factory exhaust; the 138PT-04 gives 4398 m³/h at 980W for kitchen extraction; the 072PS-06 gives 2266 m³/h at 175W for light factory exhaust. All share the 310mm aluminum impeller and 3 kg frame.