LBBE3G250-092NS-12 EC FFU Centrifugal Fan

LBBE3G250-092NS-12 EC FFU Centrifugal Fan

LBBE3G250-092NS-12 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44, 1531m³/h at 140W for FFU filter units and cleanroom ventilation.

LBBE3G250-072PS-15 EC Ventilation Fan

LBBE3G250-072PS-15 EC Ventilation Fan

LBBE3G250-072PS-15 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44, 1215m³/h at 90W for quiet kitchen exhaust and ventilation.

LBBE3G250-072NS-08 EC FFU Centrifugal Fan

LBBE3G250-072NS-08 EC FFU Centrifugal Fan

250mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, 1185m³/h at 85W for FFU air purifiers and new energy heat dissipation.

LBBE3G250 EC Centrifugal Fan Aluminum Alloy

LBBE3G250 EC Centrifugal Fan Aluminum Alloy

250mm EC backward curved centrifugal fan with aluminum alloy impeller and IP55 sealing, 520–1000W options delivering up to 3708m³/h for factory and HVAC cooling.

LBBE3G225-072PS-11 EC Kitchen Exhaust Fan

LBBE3G225-072PS-11 EC Kitchen Exhaust Fan

LBBE3G225-072PS-11 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44 sealing, 1112m³/h at 80W for quiet kitchen fume extraction.

LBBE3G225-072PS-01 EC Kitchen Exhaust Fan

LBBE3G225-072PS-01 EC Kitchen Exhaust Fan

LBBE3G225-072PS-01 EC backward curved centrifugal fan with PA66 impeller and IP55 sealing, delivering 1009m³/h at just 85W for quiet kitchen fume extraction.

LBBE3G225 EC Backward Curved Fan 80-190W

LBBE3G225 EC Backward Curved Fan 80-190W

LBBE3G225 EC backward curved centrifugal fan series, 80–190W stepless speed control, PA66 impeller, IP54/IP44 and Class F insulation for factory, hotel and AC cabinet ventilation.

LBBE3G220-072PS-10 EC EFU Centrifugal Blower

LBBE3G220-072PS-10 EC EFU Centrifugal Blower

LBBE3G220-072PS-10 energy-saving EC backward curved centrifugal fan with PA66 impeller, IP44 rated, built for EFU exhaust units and commercial kitchen fume extraction.

LOBISOONG LBA6038 Series
60mm x 60mm x 38mm
DC Axial Fan

LOBISOONG LBA6038 Series 60mm x 60mm x 38mm DC Axial Fan

LOBISOONG LBA6038 Series — 60×60×38mm DC Axial Fan

The LOBISOONG LBA6038 series is a high-static-pressure DC axial fan built in the compact 60mm × 60mm × 38mm format. The extra thickness over standard 25mm fans allows a deeper blade profile and a more powerful motor, making this series suited to applications where back pressure is significant and ordinary slim fans stall.

Performance Range. Typical 6038-class fans are offered in 12V, 24V, and 48V DC versions. Speed spans roughly 6,000 to 11,000 RPM, producing airflow from around 26 CFM to 58 CFM depending on the grade. Static pressure is the defining strength of this size: high-speed variants reach approximately 1.6 in H₂O (≈400 Pa), enough to push air through dense heatsinks, filters, or narrow ducting. Noise correspondingly ranges from about 39 dBA at the low end to 59 dBA at full speed.

Construction & Reliability. The frame and impeller are commonly molded from UL 94V-0 rated PBT thermoplastic with glass-fiber reinforcement for rigidity. Dual ball bearings are standard in this class, with operating life often rated at 70,000 hours and locked-rotor protection available. Optional PWM control, tach output, and IP68 sealing support speed regulation and harsh-environment use.

Typical Applications. The 6038 format is widely used in servers, telecom equipment, stage lighting, industrial power supplies, and compact inverter or battery-fixture cooling, where a 60mm footprint must still deliver meaningful pressure.

Note: Specifications vary by exact LBA6038 part suffix. Confirm voltage, airflow curve, bearing type, and noise with the official LOBISOONG datasheet for the specific configuration.

LOBISONG LBG8015 Series
80mm x 80mm x 15mm
DC Axial Fan

LOBISONG LBG8015 Series 80mm x 80mm x 15mm DC Axial Fan

LOBISONG LBG8015 Series — 80×80×15mm DC Axial Fan

The LOBISONG LBG8015 series is a slim-profile brushless DC axial fan designed for space-constrained thermal management. Measuring 80mm × 80mm × 15mm, it delivers reliable forced-air cooling where standard 25mm-thick fans cannot fit, making it a practical choice for compact electronics and dense equipment layouts.

Electrical & Performance Options. The series is typically available in 5V, 12V, 24V, and 48V DC versions to suit different system rails. Speed ranges commonly span from 1,800 RPM to 4,800 RPM, producing airflow in the range of approximately 20–48 CFM depending on the speed grade and blade design. Static pressure reaches up to roughly 0.23 in H₂O (57.3 Pa) at the high end, sufficient for pushing air through moderately restrictive vents or heatsink fins.

Bearing & Life. Units are offered with sleeve bearings for cost-sensitive, low-noise applications, or dual ball bearings for higher durability and wider temperature tolerance—ball-bearing variants are often rated for 70,000 hours of operation. Motor construction is 4-pole brushless DC, with locked-rotor protection available on higher-tier models.

Construction & Compliance. The frame and impeller are typically molded from UL 94V-0 rated PBT thermoplastic, offering flame resistance and dimensional stability. Standard lead wires are UL1007 AWG22/24 with red (+) and black (–) polarity; 2-wire, 3-wire (tach/FG), and PWM variants may be available depending on configuration. Many 8015-class fans carry UL, CE, and RoHS certifications, and IP-protected versions exist for dusty or splash-prone environments.

Typical Applications. Thanks to its 15mm thickness, the LBG8015 series is well suited for compact power supplies, network appliances, projectors, LED drivers, embedded PCs, and portable instrumentation where vertical clearance is limited but active cooling is still required.

Note: For definitive voltage ratings, airflow curves, noise levels, and bearing-life figures for a specific LBG8015 part number, request the official LOBISONG datasheet or confirm the exact model suffix with the supplier, as specifications vary by configuration.

LOBISONG LBG8020 Series
80mm x 80mm x 20mm
DC Axial Fan

LOBISONG LBG8020 Series 80mm x 80mm x 20mm DC Axial Fan

The LOBISONG LBG8020 Series is an 80mm × 80mm × 20mm DC axial fan line built for slim-profile thermal management where the standard 25mm thickness will not fit. While a model-specific LOBISONG datasheet for the LBG prefix is not publicly indexed, the 8020 platform shares well-defined performance and construction conventions across the industry that define its operating envelope.

Performance range. Typical 8020 fans run from roughly 2,000 RPM to 4,000 RPM, producing airflow in the 22 CFM to 49 CFM range and static pressure from about 1.3 to 5.2 mmH₂O. Noise scales from a quiet ~22 dBA at the low-speed end to around 37 dBA at maximum speed. Nominal voltage options commonly include 5 VDC, 12 VDC, and 24 VDC, with some variants extending to 48 VDC. For reference, a representative mid-speed 12 VDC unit delivers approximately 38 CFM at 3,000 RPM and 29 dBA, while a low-speed sleeve-bearing version can drop to around 25 CFM and 23.6 dBA.

Construction and bearing options. Housings and impellers are molded from UL94V-0 rated PBT thermoplastic, with ribbed frame designs for structural rigidity. Bearing choices span sleeve bearing, ball bearing (single or dual), and in some lines fluid dynamic bearing, allowing a trade-off between cost, service life, and mounting orientation. Lead wires are typically AWG 26 UL1007 style, and optional tachometer output, locked-rotor alarm, and PWM speed control are commonly offered for system-level thermal regulation. The 20mm depth is the defining constraint of this series, trading a modest reduction in airflow capacity against the 25mm standard in exchange for space savings in dense enclosures.

Typical applications. The 80×80×20 mm footprint suits low-profile power supplies, 1U/2U rack equipment, thin-client and set-top electronics, LED drivers, and compact industrial controllers where vertical clearance is limited. It is also a common choice for retrofit cooling in legacy equipment originally designed around 20mm-thick fans, and for prototyping and custom enclosures where every millimeter of internal height matters.

LOBISONG LBF8025 Series
80mm x 80mm x 25mm
DC Axial Fan

LOBISONG LBF8025 Series 80mm x 80mm x 25mm DC Axial Fan

The LOBISONG LBF8025 Series is a line of 80mm × 80mm × 25mm DC axial fans positioned for cost-effective, general-purpose cooling in compact electronic and industrial enclosures. While LOBISONG-specific datasheets for the LBF prefix are not widely published, the series shares the standard 8025 platform specifications common to this fan class.

Performance range. Typical 8025 fans span speeds from approximately 2,000 RPM to 6,000 RPM, with airflow ranging from roughly 25.6 CFM to 76.87 CFM and static pressure from about 1.60 to 14.29 mmAq. Noise output scales accordingly, from a quiet 22.0 dBA at the low end up to approximately 48 dBA at maximum speed. Standard voltage options include 5 VDC, 12 VDC, and 24 VDC, with 48 VDC variants available in the broader 8025 category.

Construction and bearing options. Frames and impellers are molded from PBT thermoplastic (often UL94V-0 rated for flame retardancy). Bearing choices typically include sleeve bearing, hydraulic bearing, and dual ball bearing, with sleeve bearings offering roughly 25,000 hours of life and ball-bearing versions reaching 50,000 hours or more. Lead wires are commonly UL2468 AWG #26 or equivalent, with red positive and black negative conductors. Operating temperature is generally rated from −10 °C to +70 °C.

Typical applications. The 80×80×25 mm form factor makes the LBF8025 series suitable for power supplies, control cabinets, 3D printer electronics, battery chargers, and general OEM equipment cooling. Optional FG tach signal and PWM speed control are frequently available for system-level thermal regulation.

LOBISONG LBMR8025 Series
80mm x 80mm x 25mm
DC Axial Fan

LOBISONG LBMR8025 Series 80mm x 80mm x 25mm DC Axial Fan

The LOBISONG LBMR8025 Series is a family of 80mm × 80mm × 25mm DC axial fans engineered for space-constrained thermal management where dependable, continuous airflow is required. Built around a brushless DC external-rotor motor, the series is available in 12 VDC and 24 VDC configurations to suit common industrial and electronics power rails.

Performance range. Typical operating speeds span roughly 3,000 RPM to 6,000 RPM, producing airflow between 39.67 and 76.87 CFM with static pressure from 3.80 to 14.29 mmAq. Acoustic noise across this range is rated at 32.2 to 48.60 dBA, depending on the speed variant selected. For a representative mid-range point, a 24 VDC unit running at 3,000 RPM delivers approximately 40 CFM at a low 27 dBA noise level.

Construction and bearing options. The frame and impeller are molded from PBT for dimensional stability and resistance to elevated temperatures. Bearing choices include dual ball bearing, long-life sleeve, and FDB (Fluid Dynamic Bearing) systems, allowing users to balance service life against cost and orientation sensitivity. The fans are rated for operation from −10 °C to +70 °C.

Typical applications. The 80×80×25 mm footprint makes the LBMR8025 series suitable for inverters, welders, power supplies, 3D printer electronics, custom enclosures, and general industrial cabinet cooling. With its brushless motor design, the series supports long-duration operation with low maintenance and is commonly supplied with 2-wire leads or JST-style connectors for drop-in installation.

LBBE3G220-072PS-01 EC Heat Dissipation Fan

LBBE3G220-072PS-01 EC Heat Dissipation Fan

220mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, delivers 937m³/h for kitchen exhaust and industrial heat dissipation.

LBBE3G220-072NS-07 EC Cabinet Cooling Fan

LBBE3G220-072NS-07 EC Cabinet Cooling Fan

220mm EC backward curved centrifugal fan with PA66 impeller, IP55/IP44, 937m³/h airflow for electrical cabinet and enclosure heat dissipation.