LBBE3G225-072PS-01 EC Kitchen Exhaust Fan

LBBE3G225-072PS-01 EC backward curved centrifugal fan with PA66 impeller and IP55 sealing, delivering 1009m³/h at just 85W for quiet kitchen fume extraction.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G225-072PS-01 is a 225mm EC backward curved centrifugal fan developed for kitchen fume extraction and low-noise exhaust duty. As a backward curved centrifugal fan built around a PA66 engineering plastic impeller, it moves 1009 m³/h at 2300 r/min with only 85W shaft power, which keeps kitchen exhaust systems quiet and economical to run through long cooking hours. The unit is rated IP55 with Class F insulation, operates on 230V 50/60Hz, and holds steady across a -25℃ to +60℃ ambient range under S1 continuous operation. Inside this four-variant 225mm family, this backward curved centrifugal fan is the low-power entry model, sized for standard commercial hoods rather than heavy industrial ducts.

Model Power Speed Air Flow
LBBE3G225-072PS-01 85W 2300 r/min 1009m³/h
LBBE3G225-072PS-02 115W 2600 r/min 1185m³/h
LBBE3G225-072PS-03 170W 3100 r/min 1313m³/h
LBBE3G225-092PS-04 230W 3600 1360m³/h

Product Advantages

1. PA66 Impeller Built for Grease-Laden Airstreams

The defining part of this backward curved centrifugal fan is its 225mm PA66 engineering plastic impeller. PA66 resists grease adhesion, heat aging and chemical attack far better than commodity plastics, so the blade surfaces stay clean and the pressure curve stays predictable even after months of pulling oil-laden kitchen air. Because a backward curved centrifugal fan generates static pressure rather than sheer velocity, it keeps delivering 1009 m³/h once air passes through a grease filter, a hood plenum and a length of duct. The molded blade profile also evens out airflow, which lowers the broadband noise that normally comes from turbulence at the impeller outlet.

2. 85W EC Motor for Quiet, Low-Cost Continuous Running

This backward curved centrifugal fan is driven by a brushless EC motor rated at 85W, and that low input figure is the reason it suits hoods that run all day. The EC drive converts power efficiently at part load, so a backward curved centrifugal fan of this size can be held at reduced speed overnight or during light cooking without wasting energy. Speed is steplessly adjustable rather than tapped in fixed steps, letting the exhaust controller ramp the backward curved centrifugal fan up as fume load rises and back down when the kitchen quiets. Lower rpm also cuts the motor hum that guests notice in open-plan dining areas.Product Overview

Product Overview

Product Overview

Product Overview

3. IP55 Sealing Against Grease Mist and Washdown

Kitchen exhaust is an unusually hostile place for a motor, and this backward curved centrifugal fan answers it with IP55 protection. The sealed housing keeps grease mist, flour dust and cleaning splashes away from the windings and bearings, so a backward curved centrifugal fan installed in a hood stays reliable where an open-frame blower would seize. Because the motor is shielded, this backward curved centrifugal fan needs no oil-mist enclosure of its own, which simplifies hood design and reduces the parts count in a packaged exhaust unit.

4. Class F Insulation and a Wide Thermal Window

Class F insulation gives this backward curved centrifugal fan thermal headroom, which matters because hood interiors trap heat around the motor. A backward curved centrifugal fan running at 2300 r/min in a warm plenum still needs stable dielectric performance, and Class F delivers it across the rated -25℃ to +60℃ ambient range. The 230V 50/60Hz input means the same backward curved centrifugal fan ships into both 50Hz and 60Hz markets, cutting SKU proliferation for exporters. Paired with sealed ball bearings and an S1 duty rating, this backward curved centrifugal fan is specified for non-stop operation with no relubrication interval.

5. Four Output Steps on One 225mm Platform

All four models in this PS series share a 225mm impeller diameter and a 2 kg frame, so one hood cut-out accepts any of them. Designers can keep the mechanical envelope fixed and dial output to the job: the 072PS-01 backward curved centrifugal fan at 85W and 1009 m³/h for standard commercial hoods, the 072PS-02 at 115W and 1185 m³/h, the 072PS-03 at 170W and 1313 m³/h for factory exhaust, and the 092PS-04 at 230W and 1360 m³/h for heavy kitchen duty. That common platform lets a single backward curved centrifugal fan footprint serve several product lines, and every unit ships with CE, RoHS, ETL, BSCI, CCC and ISO certification.Product Overview

Product Overview

Application Scenarios

  • Commercial Kitchen Hood Exhaust: This backward curved centrifugal fan is the air-moving core of range hoods and under-cabinet extractors in restaurants, canteens and food courts, pulling cooking fume and steam away from workstations while keeping noise acceptable in adjacent dining areas.
  • Fume Extraction and Grease Filter Systems: Because a backward curved centrifugal fan holds pressure across filter media, it works well behind grease baffles and multi-stage filtration, where free-delivery fans would stall and lose extraction rate.
  • Packaged Kitchen Exhaust Units: OEMs building exhaust fan units specify this backward curved centrifugal fan for its compact 2 kg frame, IP55 sealing and 230V 50/60Hz compatibility, which let one assembly serve multiple export markets.
  • Light Industrial Exhaust Ventilation: Where cooking and process fumes mix, as in food processing rooms and staff canteens tied to production floors, this backward curved centrifugal fan provides steady low-power extraction without the noise penalty of high-speed blowers.

Product Overview

Product Overview

Frequently Asked Questions

Q: Is this fan powerful enough for a commercial kitchen hood? A: For standard hoods, yes. This backward curved centrifugal fan delivers 1009 m³/h at 2300 r/min on 85W, which covers ordinary commercial cooking lines. For longer ducts, heavier grease filtration or high-volume kitchens, step up to the 092PS-04 model at 230W and 1360 m³/h.

Q: Will grease damage the motor? A: The motor is sealed to IP55, so grease mist and washdown splashes stay out of the windings and bearings, and the PA66 impeller resists grease adhesion on the blade surfaces. That combination is why this backward curved centrifugal fan is specified for continuous kitchen duty.

Q: Can the speed be adjusted and can it run all day? A: Both. The EC motor supports stepless speed regulation, so output can track actual fume load, and the unit is rated S1 continuous operation with sealed ball bearings for non-stop running inside the -25℃ to +60℃ range.

LBBE3G225-072PS-01 EC Kitchen Exhaust Fan

LBBE3G225-072PS-01 EC backward curved centrifugal fan with PA66 impeller and IP55 sealing, delivering 1009m³/h at just 85W for quiet kitchen fume extraction.

Request a Quote

Featured Products

lbbe3g225 072ps 01 ec kitchen exhaust fan-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000