LBBE3G250-072PS-01 EC Low Noise Dust Fan

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G250-072PS-01 is a 250mm low-noise EC backward curved centrifugal fan built for dust removal and air supply duty in air conditioning and purification equipment. Using a PA66 engineering plastic impeller on an external rotor EC motor, this backward curved centrifugal fan delivers 1185 m³/h at 1810 r/min on only 85W shaft power, which keeps acoustic output low enough for installation close to occupied rooms while still pushing air through filter screens and duct runs. The u nit is sealed to IP55, insulated to Class F, wired for 230V 50/60Hz, and rated S1 continuous operation across -25℃ to +60℃. Within this four-variant 250mm PS family, this backward curved centrifugal fan is the quiet entry model, matched to standard dust removal hoods and AC supply air boxes.

Model Power Speed Air Flow
LBBE3G250-072PS-01 85W 1810 r/min 1185m³/h
LBBE3G250-072PS-02 115W 2180 r/min 1236m³/h
LBBE3G250-072PS-04 169W 2570 r/min 1478m³/h
LBBE3G250-092PS-05 230W 2700 r/min 1648m³/h

Product OverviewProduct OverviewProduct Overview

Product Overview

Product Advantages

1. Low-Noise Blade Path on a PA66 Impeller

Noise is the first specification this backward curved centrifugal fan was designed around. The 250mm PA66 impeller uses a backward-inclined blade exit angle that reduces the velocity difference between the blade wake and the volute flow, which is the main source of broadband noise in a compact blower. Because a backward curved centrifugal fan builds static pressure instead of sheer velocity, it moves 1185 m³/h without the high exit speeds that make axial fans sound harsh through a duct. The molded PA66 blades also stay geometrically stable through long duty cycles, so this backward curved centrifugal fan does not develop imbalance or rumble as it ages.

2. 85W External Rotor EC Motor with Stepless Speed

This backward curved centrifugal fan uses an external rotor EC motor, where the magnet ring sits on the rotor hub and the stator is wound inside. That architecture removes the belt-and-pulley losses of conventional blowers and produces high torque at low speed, which is exactly what a quiet ducted installation needs. Rated at 85W, this backward curved centrifugal fan can be throttled steplessly rather than switched between taps, so a controller can trim airflow as filter screens load and settle it back after cleaning. Since power drops roughly with the cube of speed, this backward curved centrifugal fan saves substantial energy in systems that run all day at partial load.

3. IP55 Sealing for Dusty Removal Service

Dust removal duty is unforgiving, and this backward curved centrifugal fan is sealed to IP55 to survive it. Fine particulate from grinding, cutting or powder handling quickly embeds in an open motor and shortens bearing life, while a sealed backward curved centrifugal fan keeps that dust out of the windings and bearing cavity. The same rating protects against washdown splashes in food and pharmaceutical areas, so one backward curved centrifugal fan platform serves both dusty industrial hoods and cleanable supply air boxes without a secondary enclosure.Product Overview

Product Overview

Product Overview

Product Overview

4. Class F Insulation and Stable Performance Window

Class F insulation gives this backward curved centrifugal fan winding headroom under sustained load, which matters when the motor sits in a tight supply air box with limited cooling flow around it. The rated ambient range of -25℃ to +60℃ covers cold storage intake, unheated workshops and warm plant rooms without derating, and S1 duty means this backward curved centrifugal fan is specified for non-stop operation rather than intermittent cycling. The 230V 50/60Hz input keeps one SKU valid for both 50Hz and 60Hz markets, simplifying export stock planning for OEMs.

5. Four Output Steps, One 250mm Footprint

All four models in this PS series share a 250mm impeller diameter and a 2 kg frame, so a single duct collar or cabinet opening accepts any of them. Designers fix the mechanical envelope and size the airflow: this 072PS-01 backward curved centrifugal fan at 85W and 1185 m³/h for quiet dust removal and AC supply air, the 072PS-02 at 115W and 1236 m³/h for lighter factory exhaust, the 072PS-04 at 169W and 1478 m³/h for heavier factory duty, and the 092PS-05 at 230W and 1648 m³/h for high-capacity kitchen exhaust. That common platform lets a single backward curved centrifugal fan reference cover several product lines, and every unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification with maintenance-free sealed ball bearings.

Application Scenarios

  • Dust Removal and Collection Equipment: This backward curved centrifugal fan serves dust removal hoods, grinding benches and powder handling enclosures, holding extraction against pre-separators and filter bags where free-delivery fans would stall.
  • Air Conditioning Supply Air Units: In fan coil cabinets and packaged supply air boxes, this backward curved centrifugal fan pushes conditioned air through coils and distribution ducts quietly, which matters when the unit sits above a ceiling near occupied rooms.
  • Air Purification Modules: Where a purifier needs steady pressure across filter media, this backward curved centrifugal fan maintains clean air delivery as media loads, and its stepless EC control allows output to track actual particulate level.
  • Factory and Workshop Ventilation: For general air exchange in production areas with moderate resistance, this backward curved centrifugal fan provides steady low-power airflow and needs no relubrication over its service life.

Frequently Asked Questions

Q: Why is this fan described as low noise? A: The blade exit angle on this backward curved centrifugal fan reduces wake turbulence at the volute, and the external rotor EC motor runs at a modest 1810 r/min. Combined with 85W input, this backward curved centrifugal fan produces a low sound signature suitable for ceiling-mounted supply air units.

Q: Is 1185 m³/h enough for dust removal duty? A: For standard hoods and filter benches, yes. This backward curved centrifugal fan holds 1185 m³/h against typical filter screen resistance. For heavier extraction, the 072PS-04 and 092PS-05 models step up to 1478 and 1648 m³/h.

Q: Can the speed be adjusted and can it run continuously? A: Both. This backward curved centrifugal fan supports stepless speed regulation through its EC drive, and it is rated S1 continuous operation with sealed ball bearings for non-stop running inside the -25℃ to +60℃ ambient range.