LBBE3G250 EC Centrifugal Fan Aluminum Alloy

250mm EC backward curved centrifugal fan with aluminum alloy impeller and IP55 sealing, 520–1000W options delivering up to 3708m³/h for factory and HVAC cooling.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G250-102 series is a high-power family of 250mm EC backward curved centrifugal fans built for factory heat dissipation, hotel ventilation and air conditioning cabinet cooling where airflow demand runs well beyond light-duty hood work.Each unit in this family uses a die-cast aluminum alloy impeller rather than plastic, paired with a three-phase EC motor and sealed ball bearings, and the range climbs from 520W at 2472 m³/h to 1000W at 3708 m³/h. All three models run on 400V/230V 50/60Hz, carry IP55 protection and Class F insulation, and hold S1 continuous duty across -25℃ to +60℃. Across the wider LBBE3G225/250 platform, this backward curved centrifugal fan family covers 1112 to 3708 m³/h, letting one design envelope serve both compact hoods and large plant-room equipment.

Product Overview

Product Advantages

1. Aluminum Alloy Impeller for High-Speed Stress

What separates this backward curved centrifugal fan from plastic-impeller units is its die-cast aluminum alloy impeller. At 3650 to 4100 r/min, centrifugal stress on the blades is high enough that plastics would need heavy reinforcement, while aluminum alloy holds blade geometry rigid with no creep and no heat-driven softening. That rigidity is why this backward curved centrifugal fan can run at 3708 m³/h without the impeller distorting, and it also means the blade surfaces survive airstreams carrying grit, dust or process heat. The metal impeller adds rotating mass that damps vibration, so this backward curved centrifugal fan stays smoother at speed than a light plastic rotor would.

2. 520W to 1000W EC Output in Three Steps

This backward curved centrifugal fan family is deliberately split into three power tiers so a system can be sized honestly instead of over- or under-blown. The 102NS-10 model runs 520W at 3650 r/min for 2472 m³/h, aimed at factory floor heat dissipation. The 102NS-20 raises output to 750W at 4100 r/min for 3039 m³/h, matching hotel ventilation with long ducts and high resistance. The 102NT-21 delivers 1000W at 3860 r/min for 3708 m³/h, sized for air conditioning cabinets pushing air through dense coil banks. Because all three are 250mm and 2 kg, one mounting cut-out accepts any of them, so a single backward curved centrifugal fan platform can cover several product lines.

Product Overview

Product OverviewProduct Overview

Product Overview

3. Three-Phase EC Drive with Stepless Speed Control

Each model uses an electronically commutated motor rather than a fixed-speed induction motor, so this backward curved centrifugal fan can be throttled steplessly to match real heat load. On a plant floor where peak load lasts only a few hours, turning the backward curved centrifugal fan down instead of damping airflow cuts power consumption dramatically, because fan power scales roughly with the cube of speed. The EC drive also limits starting current, protecting contactors and upstream distribution in cabinet and plant-room installations, and it keeps efficiency high at partial speed where conventional motors fall off.

4. IP55 Sealing and Dual 400V/230V Input

The IP55 rating on this backward curved centrifugal fan keeps dust and splashing water out of the windings and bearings, which matters in dusty production halls, semi-outdoor plant rooms and washdown-adjacent installations. Because the housing is fully sealed, a backward curved centrifugal fan installed next to machining or washing equipment does not need a secondary enclosure. Input voltage is rated 400V/230V at 50/60Hz, so the same backward curved centrifugal fan can be wired for European three-phase supplies or single-phase 230V regions, which simplifies export stocking for OEMs shipping into multiple markets.

Product Overview

Product Overview

Application Scenarios

  • Factory Heat Dissipation: The 102NS-10 variant at 520W and 2472 m³/h suits continuous background air exchange on production floors, removing machine heat without the noise of a high-speed blower.
  • Hotel and Commercial Ventilation: The 102NS-20 at 750W and 3039 m³/h covers hotel plant rooms, corridor ventilation and back-of-house ducts where static pressure losses are substantial.
  • Air Conditioning Cabinet Cooling: The 102NT-21 at 1000W and 3708 m³/h is sized for AC cabinets and air handling compartments, pushing air through coil banks and filter stages in climate control equipment.
  • Industrial Enclosure and Equipment Cooling: All three models serve electrical enclosures, control panels and packaged ventilation units where this backward curved centrifugal fan must deliver directed high-pressure airflow against internal resistance.

Frequently Asked Questions

Q: Why aluminum alloy instead of plastic for the impeller? A: At 3650–4100 r/min the centrifugal stress on the blades is severe. An aluminum alloy impeller in this backward curved centrifugal fan keeps blade geometry rigid without creep or heat softening, resists abrasive airstreams, and adds rotating mass that damps vibration at speed.

Q: Which model fits my airflow requirement? A: The 102NS-10 gives 2472 m³/h at 520W for factory floors; the 102NS-20 gives 3039 m³/h at 750W for hotel ducts; the 102NT-21 gives 3708 m³/h at 1000W for AC cabinets. All three are 250mm and 2 kg, so the same cut-out accepts any of these.

Q: Can this fan run on both 400V and 230V supplies? A: Yes. The rated input is 400V/230V at 50/60Hz, so this backward curved centrifugal fan can be wired for three-phase European supplies or single-phase 230V regions, and it runs continuously under S1 duty within the -25℃ to +60℃ range.

LBBE3G250 EC Centrifugal Fan Aluminum Alloy

250mm EC backward curved centrifugal fan with aluminum alloy impeller and IP55 sealing, 520–1000W options delivering up to 3708m³/h for factory and HVAC cooling.