LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal fan, 7-blade rotor, 2235m³/h at 160W, 70-80dB for cleanrooms.
The LBBE3G310-092NS-20 is a 310mm low-pressure EC backward curved centrifugal fan designed for cleanroom air delivery, equipment cooling and low-noise ventilation. Its seven-blade impeller is driven by a brushless EC motor rated at 160W, producing 2235 m³/h at 1850 r/min with outlet noise registered in the 70–80 dB band. The assembly offers IP54/IP44 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 230V 50/60Hz. As the entry model of this three-variant 310mm NS family, this backward curved centrifugal fan covers standard cleanroom and cooling ventilation, while the other two variants reach 150W and 360W to serve comparable light-duty and mid-range air movement.
| Model | Power | Speed | Air Flow |
| LBBE3G310-92NS-20 | 160 W | 1850 r/min | 2235 m³/h |
| LBBE3G310-92NS-17 | 150W | 1750 r/min | 2410 m³/h |
| LBBE3G310-102NS-16 | 360W | 2149 r/min | 2869 m³/h |




This backward curved centrifugal fan uses a seven-blade impeller whose spacing spreads the airflow pulse more evenly than a coarse three- or five-blade wheel, reducing discrete blade-pass hum near occupied cleanroom zones. The low-pressure rotor moves 2235 m³/h through light ducting, pre-filters and panel grilles without forcing high tip speeds, which keeps noise within the 70–80 dB band and limits vibration transmitted to the housing. The smooth impeller surface wipes down easily during routine room maintenance, an advantage in spaces where airborne contamination control matters.
A brushless electronically commutated motor forms the power core of this 160W unit, eliminating brushes and commutator wear from the maintenance list. The EC controller holds efficiency across the speed range, so the backward curved centrifugal fan can be slowed during low-occupancy periods instead of throttled behind a damper that wastes energy as pressure loss. Stepless speed trimming lets the air-handling system balance cleanroom make-up air against noise and power draw, and soft-start ramp-up protects upstream circuits from inrush current. Brushless operation keeps motor maintenance down to sealed-bearing inspection only.
The family is offered in IP54 and IP44 sealing grades so the blower can be matched to its mounting zone. IP54 blocks dust particles above 1mm and resists splashing water for plant rooms and semi-protected indoor installations; IP44 suits enclosed cabinets, ceiling plena and ducted housings behind intake panels. The sealed housing keeps particulate away from Class F windings and ball bearings, helping this backward curved centrifugal fan hold consistent airflow over years of daily use where an open-frame motor would collect grit and drift in output.
Class F winding insulation provides thermal reserve for sustained full-load running, particularly relevant when the blower sits inside a closed air-handling cabinet that limits motor self-cooling. Rated from -25℃ to +60℃, the unit handles cool cleanrooms, warm commercial spaces and seasonal temperature swings without derating, and S1 duty confirms the backward curved centrifugal fan is engineered for non-stop continuous operation rather than intermittent short bursts. The 230V 50/60Hz input matches standard commercial grids for export cleanroom and ventilation projects.
All three models in this family share the 310mm impeller envelope, so the duct collar and mounting interface can be standardized across projects. The NS-20 backward curved centrifugal fan at 160W and 2235 m³/h covers standard cleanroom and cooling ventilation; the NS-17 at 150W and 2410 m³/h handles comparable light-duty airflow; the NS-16 at 360W and 2869 m³/h serves mid-range ventilation and equipment cooling. Sealed ball bearings are relubrication-free, each unit carries ISO, BSCI, ETL, CE, EMC, RoHS and GS certification, and the factory supports OEM/ODM customization for bulk purification projects.


Q: What airflow does the NS-20 deliver? A: This backward curved centrifugal fan delivers 2235 m³/h at 1850 r/min on 160W, classified as a low-pressure fan for standard cleanroom ventilation, equipment cooling and general air movement.
Q: How loud is the unit and can speed be adjusted? A: The rated noise range is 70–80 dB, and the brushless EC motor supports stepless speed regulation, so the backward curved centrifugal fan can be trimmed to a quieter, lower-power running point during light-load periods.
Q: Which variants share this 310mm platform? A: The NS-17 gives 2410 m³/h at 150W; the NS-16 gives 2869 m³/h at 360W. Both share the 310mm impeller platform, sealed ball bearings and S1 continuous duty rating.