LBBE3G310-102NS-19 EC low-pressure backward curved centrifugal fan, 7-blade rotor, 2936m³/h at 370W, 70-80dB for cleanrooms.
The LBBE3G310-102NS-19 is a 310mm low-pressure EC backward curved centrifugal fan designed for cleanroom air delivery, equipment heat dissipation and low-noise ventilation. Its seven-blade impeller is driven by a brushless EC motor rated at 370W, producing 2936 m³/h at 2300 r/min with outlet noise held in the 70–80 dB band. The assembly offers IP54/IP44 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 230V 50/60Hz. As the entry model of this four-variant 310mm NS/NT family, this backward curved centrifugal fan covers standard cleanroom and cooling ventilation, while the other three variants scale to 450W, 980W and 1588W, reaching 5593 m³/h for high-volume air handling.
| Model | Power | Speed | Air Flow |
| LBBE3G310-102NS-19 | 370 W | 2300 r/min | 2936 m³/h |
| LBBE3G310-102NS-18 | 450W | 2600 r/min | 2884 m³/h |
| LBBE3G310-138NT-05 | 980W | 2600 r/min | 4398 m³/h |
| LBBE3G310-138NT-25 | 1588W | 3300 r/min | 5593 m³/h |
This backward curved centrifugal fan uses a seven-blade impeller whose spacing spreads the airflow pulse more evenly than a coarse three- or five-blade wheel, reducing discrete blade-pass hum near occupied cleanroom zones. The low-pressure, high-volume rotor moves 2936 m³/h through light ducting, pre-filters and panel grilles without forcing high tip speeds, which keeps noise within the 70–80 dB band and limits vibration transmitted to the housing. The impeller surface is smooth and easy to wipe down during routine room maintenance, an advantage in spaces where airborne contamination control matters.
A brushless electronically commutated motor forms the power core of this 370W unit, eliminating brushes and commutator wear from the maintenance list. The EC controller holds efficiency across the speed range, so the backward curved centrifugal fan can be slowed during low-occupancy periods instead of throttled behind a damper that wastes energy as pressure loss. Stepless speed trimming lets the air-handling system balance cleanroom make-up air against noise and power draw, and soft-start ramp-up protects upstream circuits from inrush current. Brushless operation also keeps motor maintenance to sealed-bearing inspection only.




The family is offered in IP54 and IP44 sealing grades so the blower can be matched to its mounting zone. IP54 blocks dust particles above 1mm and resists splashing water for plant rooms and semi-protected indoor installations; IP44 suits enclosed cabinets, ceiling plena and ducted housings behind intake panels. The sealed housing keeps particulate away from Class F windings and ball bearings, helping this backward curved centrifugal fan hold consistent airflow over years of daily use where an open-frame motor would collect grit and drift in output.
Class F winding insulation provides thermal reserve for sustained full-load running, particularly relevant when the blower sits inside a closed air-handling cabinet that limits motor self-cooling. Rated from -25℃ to +60℃, the unit handles cool cleanrooms, warm commercial spaces and seasonal temperature swings without derating, and S1 duty confirms the backward curved centrifugal fan is engineered for non-stop continuous operation rather than intermittent short bursts. The 230V 50/60Hz input matches standard commercial grids for export cleanroom and ventilation projects.
All four performance models share the 310mm impeller envelope, so the duct collar and mounting interface can be standardized across projects. The NS-19 backward curved centrifugal fan at 370W and 2936 m³/h covers standard cleanroom and cooling ventilation; the NS-18 at 450W and 2884 m³/h handles comparable medium-duty airflow; the NT-05 at 980W and 4398 m³/h serves high-volume air handling; the NT-25 at 1588W and 5593 m³/h tops the range for large plant and ventilation systems. Sealed ball bearings are relubrication-free, each unit carries ISO, BSCI, ETL, CE, EMC, RoHS and GS certification, and the factory supports OEM/ODM customization for bulk purification projects.


Q: What airflow does the NS-19 deliver? A: This backward curved centrifugal fan delivers 2936 m³/h at 2300 r/min on 370W, classified as a low-pressure fan for standard cleanroom ventilation, equipment cooling and general air movement.
Q: Is the unit suitable for regulated cleanroom installation? A: The blower supports general cleanroom ventilation and air movement with its seven-blade rotor, sealed bearings and low-noise operation. Any classified cleanroom or medical-grade certification must be verified against local regulatory standards and the project's cleanroom grade before specification.
Q: Which variants share this 310mm platform? A: The NS-18 gives 2884 m³/h at 450W; the NT-05 gives 4398 m³/h at 980W; the NT-25 gives 5593 m³/h at 1588W. All share the 310mm impeller platform and S1 continuous duty rating.
LBBE3G310-102NS-19 EC low-pressure backward curved centrifugal fan, 7-blade rotor, 2936m³/h at 370W, 70-80dB for cleanrooms.