LBBE3G310-102NS-18 EC Purifier Blower

LBBE3G310-102NS-18 EC medium-pressure backward curved centrifugal fan, galvanized/aluminum rotor, 2884m³/h at 450W for purifiers.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G310-102NS-18 is a 310mm medium-pressure EC backward curved centrifugal fan engineered for air purifier units, industrial ventilation and general heat dissipation. Its galvanized sheet or aluminum alloy impeller is driven by a brushless EC motor rated at 450W, producing 2884 m³/h at 2600 r/min with outlet noise in the 73–85 dB band. The assembly offers IP55/IP54/IP44 sealing, Class F insulation

, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 400V/230V 50/60Hz. As the highest-output model of this four-variant 310mm NS family, this backward curved centrifugal fan provides the pressure needed to push air through multi-stage purification filters, while the remaining three variants cover factory ventilation, kitchen exhaust and fire smoke exhaust duty.

Model Power Speed Air Flow
LBBE3G310-102NS-18 450W 2600 r/min 2884 m³/h
LBBE3G310-102NS-19 370W 2300 r/min 2936 m³/h
LBBE3G310-092NS-20 160W 1850 r/min 2235m³/h
LBBE3G310-072NS-21 175W 1710 r/min 2266m³/h

Product Overview

Product Overview

Product Advantages

1. Medium-Pressure Rotor Built for Filter Resistance

Air purifiers place a series of filter stages between intake and outlet, each adding pressure drop that a free-delivery axial blower cannot overcome. This backward curved centrifugal fan generates medium static pressure with its backward-inclined impeller, so 2884 m³/h keeps moving after air crosses pre-filter, activated carbon and HEPA-style media instead of stalling as the filter loads. The 310mm rotor spreads the load across a wide blade path, and the dual galvanized or aluminum alloy options let integrators match the rotor to airstream conditions: galvanized for general dust-bearing air, aluminum for lighter cleaner air and lighter rotor weight.

2. 450W EC Drive with Stepless Speed Control

The power core of this backward curved centrifugal fan is a brushless EC motor rated at 450W, sized to hold filter pressure without belt or pulley losses. The electronically commutated controller keeps efficiency high at partial speed, so the purifier or ventilation unit can slow the blower during light occupancy rather than throttling airflow with a damper that wastes energy as pressure loss. Stepless speed trimming lets the system balance clean-air output against noise and power draw, and soft-start current ramp protects upstream circuits from inrush. Brushless operation also removes commutator wear from the service schedule.

3. Three Sealing Levels Across Purification and Plant Zones

The family ships in IP55, IP54 and IP44 grades so the blower can be matched to where it mounts. IP55 resists fine dust and directional splashing for dusty plant rooms and semi-outdoor installations; IP54 gives standard indoor dust protection; IP44 suits protected purifier cabinets and ducted housings behind intake panels. The sealed motor housing keeps particulate away from Class F windings and ball bearings, helping this backward curved centrifugal fan hold steady airflow over years of daily use where an open-frame motor would collect grit and drift in output.

Product Overview

Product Overview

Product Overview

Product Overview

4. Class F Insulation and Continuous-Duty Purification Build

Class F winding insulation provides thermal reserve for sustained full-load running, particularly relevant when the blower sits inside a closed purifier cabinet that limits motor self-cooling. Rated from -25℃ to +60℃, the unit handles cool plant rooms, warm commercial spaces and seasonal temperature swings without derating, and S1 duty confirms the backward curved centrifugal fan is engineered for non-stop continuous operation rather than intermittent short bursts. The 400V/230V 50/60Hz input covers three-phase European sites and 230V commercial grids from one model line.

5. Four Power Tiers on a Common 310mm Platform

All four models in this family share the 310mm impeller envelope and 3 kg frame, standardizing the duct collar, mounting holes and housing fitment across projects. The NS-18 backward curved centrifugal fan at 450W and 2884 m³/h leads the range for purifier and heavier plant airflow; the NS-19 at 370W and 2936 m³/h serves factory ventilation; the NS-20 at 160W and 2235 m³/h handles kitchen exhaust; the NS-21 at 175W and 2266 m³/h covers fire smoke exhaust systems. Sealed ball bearings are relubrication-free, each unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, and the factory supports OEM/ODM customization for bulk purification and ventilation projects.

Product Overview

Product Overview

Application Scenarios

  • Commercial and Industrial Air Purifiers: This backward curved centrifugal fan forms the pressure-generating core of standalone purifiers and ducted purification units, holding airflow through filter stacks in offices, workshops and public spaces.
  • Workshop Ventilation and Heat Dissipation: Mounted in ventilation boxes or wall outlets, the blower removes accumulated machine heat and dust from production floors while supplying balanced make-up air.
  • Packaged Purification Modules: System builders use the 310mm platform inside air handlers, dust collectors and filter cabinets, relying on the common frame, three sealing options and EC drive compatibility across product lines.
  • Kitchen and Smoke Exhaust (Family Variants): The NS-20 and NS-21 models extend the platform to kitchen fume extraction and fire smoke exhaust systems, where sustained exhaust duty is required.

Frequently Asked Questions

Q: Why does a purifier need a centrifugal blower? A: Filter media create pressure drop that free-air blowers cannot overcome. This backward curved centrifugal fan builds medium static pressure to keep 2884 m³/h flowing through purification stages as the filter loads, rather than losing airflow over time.

Q: What airflow does the NS-18 deliver? A: The unit delivers 2884 m³/h at 2600 r/min on 450W, with rated noise of 73–85 dB. Speed can be trimmed to a quieter, lower-power point during light-load periods.

Q: Which variants share this 310mm platform? A: The NS-19 gives 2936 m³/h at 370W; the NS-20 gives 2235 m³/h at 160W for kitchen exhaust; the NS-21 gives 2266 m³/h at 175W for smoke exhaust. All share the galvanized/aluminum impeller, 3 kg frame and S1 continuous duty rating.

LBBE3G310-102NS-18 EC Purifier Blower