Lobisong 155mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP44 – LBBE3G155-072NS-02

Lobisong 155mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP44 – LBBE3G155-072NS-02

Tailored Performance for Factory Heat Dissipation – This 155mm EC centrifugal fan variant LBBE3G155-072NS-02 features 40W rated shaft power, running at 3750 r/min with maximum airflow up to 433 m³/h. It is specially designed for factory workshop heat dissipation and ventilation.

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G175-072NS-03

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G175-072NS-03

Multiple Performance Options for Factory Ventilation– This 175mm EC centrifugal fan series provides three different performance variants to meet diverse factory ventilation demands. The LBBE3G175-072NS-03 variant comes with 85W rated shaft power, operating at 3300 r/min with maximum airflow of 742 m³/h.
LOBISONG LBMS1238-H Series
120mm x 120mm x 38mm
DC Axial Fan

LOBISONG LBMS1238-H Series 120mm x 120mm x 38mm DC Axial Fan

LOBISONG LBMS1238-H Series — 120mm × 120mm × 38mm DC Axial Fan

Product Introduction
The LOBISONG LBMS1238-H Series is a high-performance 120mm × 120mm × 38mm DC axial fan engineered for demanding thermal management. The “H” suffix indicates a high-speed, high-static-pressure variant developed for equipment where ordinary 25mm-thick fans cannot provide sufficient cooling. With its deeper 38mm frame, advanced impeller, and robust motor, the LBMS1238-H moves a large volume of air and maintains strong pressure through dense heatsinks, filters, perforated panels, and long ducts. It is an excellent choice for servers, telecom cabinets, power supplies, inverters, EV charging stations, industrial controllers, medical devices, and other compact, high-density electronics.

Frame, Impeller, and Construction
The fan measures 120 × 120 × 38mm. The housing and impeller are molded from flame-retardant PBT thermoplastic rated UL94V-0. This material provides dimensional stability, heat resistance, and safety. The impeller is dynamically balanced to reduce vibration and noise. The deep frame supports a larger motor and wider blades, increasing static pressure compared with thinner fans. The fan can be mounted horizontally or vertically without compromising bearing performance.

Bearing System and Service Life
The LBMS1238-H Series uses a dual ball bearing system. Dual ball bearings operate reliably at higher temperatures, resist shock and vibration, and avoid the lubricant migration problems associated with sleeve bearings. Under normal conditions, expected life is typically 70,000 hours at 40°C (L10). This long life reduces maintenance and improves overall system reliability, especially in continuous-duty applications.

Motor and Drive Electronics
The fan uses a brushless DC motor with integrated drive electronics. The motor is designed for high efficiency, low electromagnetic interference, and stable commutation across a wide voltage range. Internal protection helps prevent damage during startup or stall conditions. This design supports dependable operation in industrial and telecom environments.

Electrical and Performance Options
The series is available in 12V, 24V, and 48V DC versions. Typical speed ranges from about 2,500 RPM to over 6,000 RPM, depending on model. Maximum airflow can exceed 220 CFM, and maximum static pressure can reach approximately 1.2 inch H₂O or higher. Noise levels typically range from 35 to 72 dBA. Power consumption varies by voltage and speed. The H version prioritizes pressure and airflow, making it suitable for restricted airflow paths. Lower-speed models or PWM-controlled operation can reduce noise when full cooling is not required.

Control and Monitoring
Optional features include tachometer output (FG), locked rotor alarm signal (RD), and PWM speed control. FG allows the system to monitor actual fan speed. RD provides a warning if the rotor is blocked or the fan fails. PWM enables dynamic speed control based on temperature, improving acoustic performance and energy efficiency. These functions help system designers meet thermal, acoustic, and reliability targets.

Protection and Safety
The LBMS1238-H Series includes soft start, polarity protection, and auto-restart. Soft start limits inrush current at power-on. Polarity protection prevents damage from reversed supply connections. Auto-restart automatically recovers operation after a rotor lock is removed. Optional features may include locked rotor protection, over-voltage protection, and moisture protection. Lead wires and connectors can be customized to match system requirements.

Environmental Durability
The standard operating temperature range is -10°C to +70°C. For harsh environments, optional conformal coating and IP-rated protection can be specified to resist dust, moisture, and contaminants. The fan is RoHS compliant and can be designed to meet REACH requirements. These options make the LBMS1238-H suitable for outdoor cabinets, industrial floors, and transportation equipment.

Acoustic Management
Precise bearing preload, dynamic impeller balancing, and smooth motor commutation help minimize vibration and tonal noise. The fan can be paired with PWM control to lower speed during idle or low-load conditions, reducing acoustic output without sacrificing thermal safety.

Applications
Typical applications include rack servers, storage arrays, telecom base stations, network switches, power supplies, DC-DC converters, solar inverters, EV chargers, welding machines, laser systems, industrial automation, medical equipment, and HVAC air handling units. The fan is especially useful where high heat density, limited space, and dirty or restricted airflow demand a compact but powerful cooling solution.

Installation Guidelines
Use the four standard mounting holes and avoid over-tightening screws to prevent frame stress. Install a finger guard where required. Maintain adequate intake and exhaust clearance to reduce recirculation. For best results, match the fan’s airflow direction with the system’s thermal path.

Customization and Integration
LOBISONG supports OEM and ODM projects. Customers can specify voltage, speed, bearing type, airflow, static pressure, noise level, PWM curve, FG/RD output, wire length, connector type, label, and packaging. Prototypes and samples can be provided for qualification. The LBMS1238-H can be integrated into existing thermal designs with minimal modification.

Quality and Reliability
Each fan is manufactured under a strict quality management system. Production testing typically includes speed, current, power, airflow, static pressure, noise, vibration, and balance checks. Reliability testing may include high-temperature operation, thermal cycling, humidity, vibration, and life testing. This ensures consistent performance and long-term dependability.

Conclusion
The LOBISONG LBMS1238-H Series combines a 120 × 120 × 38mm form factor, dual ball bearings, high static pressure, flexible voltage options, and advanced control features. It delivers reliable, controllable cooling for demanding electronic systems. Whether used in telecom, industrial, medical, or power conversion equipment, the LBMS1238-H is a robust thermal solution for high-density designs.

LOBISONG LBG1238 Series
120mm x 120mm x 38mm
DC Axial Fan

LOBISONG LBG1238 Series 120mm x 120mm x 38mm DC Axial Fan

LOBISONG LBG1238 Series — 120mm × 120mm × 38mm DC Axial Fan. The LBG1238 is a high-performance cooling fan for continuous thermal management in compact electronics. Its 120×120×38mm frame delivers high airflow and strong static pressure, ideal for servers, telecom cabinets, power supplies, inverters, EV chargers, and industrial control equipment. Available in 12V, 24V, and 48V DC, it uses dual ball bearings for long life and reliable operation. Optional functions include tachometer output (FG), locked rotor alarm (RD), and PWM speed control. The impeller and housing are flame-retardant PBT UL94V-0. Typical performance: speed up to 5,000 RPM, airflow over 200 CFM, noise 30–70 dBA, and operating temperature -10°C to +70°C. Soft start, polarity protection, and auto-restart enhance safety. Reliable cooling for demanding applications.

LOBISONG LBMD1238 Series
120mm x 120mm x 38mm
DC Axial Fan

LOBISONG LBMD1238 Series 120mm x 120mm x 38mm DC Axial Fan

Built for tough thermal loads, the LOBISONG LBMD1238 Series is a 120×120×38 mm brushless DC axial fan. Its deep 38 mm frame drives high static pressure through dense heatsinks and filters. Choose 12 V, 24 V, or 48 V DC. Dual ball bearings ensure stable, long-life operation in any mounting position. Optional PWM adjusts speed in real time; FG and RD outputs simplify monitoring. The UL94V-0 PBT housing and impeller resist heat and flame. Typical performance: up to 5,000 RPM, 200+ CFM, 30–70 dBA, and −10°C to +70°C. Soft start, polarity protection, and auto-restart improve safety. Ideal for servers, telecom shelters, power converters, charging piles, and industrial control boxes. Quiet, efficient, and easy to integrate, it suits high-density electronics. The LBMD1238 delivers dependable, controllable airflow.

LOBISONG LBH1238 120x120x38mm DC Cooling Axial Fan

LOBISONG LBH1238 120x120x38mm DC Cooling Axial Fan

LOBISONG LBH1238 120x120x38mm DC axial fan for cabinet, server and power supply cooling; stable airflow, low noise, long service life.

LOBISONG LBMS1438 Series — 140×140×38mm DC Axial Fan

LOBISONG LBMS1438 Series — 140×140×38mm DC Axial Fan

LOBISONG LBMS1438 Series — 140×140×38mm DC Axial Fan

Product Overview

The LOBISONG LBMS1438 Series is a high-performance 140mm × 140mm × 38mm DC axial fan engineered for demanding thermal management applications. With a robust frame thickness of 38mm, this fan delivers superior static pressure and airflow compared to standard 25mm-thick alternatives, making it an ideal solution for servers, telecom cabinets, industrial inverters, and high-density electronic enclosures where reliable heat dissipation is critical.

Key Specifications

Parameter Specification
Frame Dimensions 140 × 140 × 38 mm
Rated Voltage 12 / 24 / 48 VDC (model-dependent)
Bearing Type Dual Ball Bearing
Speed Range 2,500 – 8,200 RPM
Max Airflow Up to 358.8 CFM
Max Static Pressure Up to 3.10 inch H₂O
Noise Level 29 – 77 dBA (speed-dependent)
Operating Temperature −10°C to +70°C
Expected Life 70,000 hours @ 40°C (L10)

Design & Features

The LBMS1438 Series incorporates an impeller and frame constructed from thermoplastic PBT UL94V-0 material, ensuring flame retardancy and dimensional stability under thermal stress. The ball bearing system provides reliable operation across a wide temperature range and supports any mounting orientation without the risk of lubricant migration associated with sleeve bearings.

Standard protective features include soft start (reducing inrush current at power-on), polarity protection (preventing damage from reversed supply connections), and auto-restart (automatic recovery after rotor lock removal). Optional functions such as tachometer output (FG), locked rotor alarm signal (RD), and PWM speed control enable system-level monitoring and dynamic thermal regulation.

Applications

  • Server and storage rack cooling

  • Telecom base station cabinets

  • Industrial inverters and power supplies

  • EV charging modules

  • Welding equipment and laser systems

  • HVAC air handling units

The LBMS1438 Series combines high airflow density, flexible voltage compatibility, and long service life, making it a dependable choice for engineers designing compact, high-reliability cooling systems.

Lobisong 133mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54/IP55 – LBBE3G133-072PS-02

Lobisong 133mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54/IP55 – LBBE3G133-072PS-02

The LBBE3G133-072PS-02 is a compact, energy-efficient EC backward curved centrifugal fan purpose-built for commercial kitchen fume extraction and light industrial smoke exhaust.

LBBE3G133-072NS-06 Backward Curved EC Centrifugal Fan

LBBE3G133-072NS-06 Backward Curved EC Centrifugal Fan

The LBBE3G133-072NS-06 is a compact high-performance backward curved EC centrifugal fan purpose-built for factory ventilation and industrial heat dissipation. 

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 400V IP54 – LBBE3G630-188NT Series

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 400V IP54 – LBBE3G630-188NT Series

High Power Performance & Multiple Model Options – This 630mm EC centrifugal fan series comes with 3 optional models with different power and speed specifications. The LBBE3G630-188NT-06 runs at 1300 r/min with shaft power of 2975W and airflow up to 19247 m³/h; LBBE3G630-188NT-07 reaches 1380 r/min, 3850W shaft power with airflow of 21100 m³/h; LBBE3G630-188NT-09 operates at 1760 r/min, shaft power 5570W and max airflow 21742 m³/h.

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, EC – LBBE3G500 Series

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, EC – LBBE3G500 Series

EC Energy-Saving Motor – Equipped with high-efficiency EC brushless motor, this 500mm centrifugal blower provides wide speed adjustable range, greatly reduces power consumption compared with traditional AC fans. It maintains stable performance under continuous long-time operation, bringing remarkable energy saving benefits for end users. Multiple model options are available with different power ratings from 870W up to 4270W, supporting various airflow demands up to 14214 m³/h.

LBBE(RT)320-PT-02 EC Backward Curved Centrifugal Fan for Rail Transit

LBBE(RT)320-PT-02 EC Backward Curved Centrifugal Fan for Rail Transit

Optimized for subway auxiliary inverter heat dissipation, this industrial centrifugal blower features DC stepless speed regulation, dual IP55/IP44 protection ratings, Class F insulation and rugged all-metal construction.

LOBISONG LBMS1751-H Series 171mm x 153mm x 51mm DC Axial Fan

LOBISONG LBMS1751-H Series 171mm x 153mm x 51mm DC Axial Fan

The LOBISONG LBMS1751-H Series is a 171 x 153 x 51mm axial DC fan for installations that must tolerate water as well as heat. Running on 12V, 24V or 48V, the DC fan keeps an aluminium frame and a UL94V-0 PBT impeller, weighs 0.66 kg, and can be ordered with an IP68 protection option. 

LOBISONG LBMA1751 Series 172mm x 150mm x 51mm DC Axial Fan

LOBISONG LBMA1751 Series 172mm x 150mm x 51mm DC Axial Fan

The LOBISONG LBMA1751 Series is a high-performance 172mm x 150mm x 51mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this robust cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMM1865 Series 180mm x 180mm x 65mm DC Axial Fan

LOBISONG LBMM1865 Series 180mm x 180mm x 65mm DC Axial Fan

The LOBISONG LBMM1865 Series is a robust 180mm x 180mm x 65mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMH2060 Series 200mm x 200mm x 60mm DC Axial Fan

LOBISONG LBMH2060 Series 200mm x 200mm x 60mm DC Axial Fan

The LOBISONG LBMH2060 Series is a robust 200mm x 200mm x 60mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment

LOBISONG LBMM2072 Series 208mm x 208mm x 72mm DC Axial Fan

LOBISONG LBMM2072 Series 208mm x 208mm x 72mm DC Axial Fan

The LOBISONG LBMM2072 Series is a robust 208mm x 208mm x 72mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.