LBBE(RT)320-PT-02 EC Backward Curved Centrifugal Fan for Rail Transit

Optimized for subway auxiliary inverter heat dissipation, this industrial centrifugal blower features DC stepless speed regulation, dual IP55/IP44 protection ratings, Class F insulation and rugged all-metal construction.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE(RT)320-PT-02 is a heavy-duty EC backward curved centrifugal fan purpose-engineered for urban rail transit inverter cooling applications. Optimized for subway auxiliary inverter heat dissipation, this industrial centrifugal blower features DC stepless speed regulation, dual IP55/IP44 protection ratings, Class F insulation and rugged all-metal construction. Built to withstand contProduct Overviewinuous vibration, dust and temperature fluctuations in onboard rail environments, this backward inclined EC fan delivers stable high-static-pressure airflow with low noise, providing reliable, energy-efficient thermal management for metro power electronics and railway on-board equipment.

Product Specifications

Electrical & Performance Parameters

Parameter Value
Model LBBE(RT)320-PT-02
Rated Voltage AC380–480V
Frequency 50/60Hz
Rated Power 1800W
Rated Current 2.7A
Maximum Airflow 2400 m³/h
Maximum Static Pressure 1000 Pa
Rated Speed 2800 RPM
Noise Level <79 dB(A)
Speed Control Mode DC stepless speed regulation

Product Advantages

1. Aerodynamic Backward Curved Centrifugal Design

This EC backward curved centrifugal fan adopts a precision-engineered backward inclined impeller profile, specially tuned for high-resistance heat dissipation in rail transit power equipment. The all-metal backward curved blade structure delivers outstanding static pressure performance, maintaining consistent, uninterrupted airflow even when pushing air through compact inverter cabinets and duct systems. Unlike ordinary axial fans, this backward curved centrifugal blower generates higher pressure with significantly less airflow turbulence, making it ideally suited for cooling dense power electronics inside subway auxiliary inverters. The robust metal impeller also provides exceptional structural strength and fatigue resistance, engineered to endure persistent vibration and mechanical shock from moving rail vehicles over years of continuous service.

2. High-Efficiency EC Motor with Intelligent Speed Control

Equipped with an advanced outer-rotor EC brushless motor, this rail transit EC fan delivers markedly higher energy efficiency and operational stability than conventional AC motor fans. The EC drive system supports DC stepless speed regulation, allowing system integrators to dynamically adjust fan speed based on real-time inverter temperature and actual cooling demand. This intelligent variable-speed operation of the backward curved centrifugal fan greatly reduces unnecessary power consumption during low-load conditions, cutting overall energy costs for rail transit operators. The EC motor also integrates a soft-start function that suppresses inrush current, protecting onboard power circuits and extending the motor’s service life.

3. Dual IP55/IP44 Protection Ratings

Available in IP55 or IP44 protection grades, this industrial centrifugal fan offers flexible options for different installation positions inside rail vehicles. The fully sealed motor assembly effectively blocks dust ingress and water splashes commonly found in metro carriages and equipment bays, safeguarding internal windings and bearings from particulate contamination and moisture erosion. This sealed structure prevents performance drift and electrical faults in harsh onboard operating conditions, ensuring stable operation even in environments with fine dust and humidity fluctuations. It meets the strict reliability requirements for 24/7 uninterrupted operation of urban rail transit equipment.

4. Wide Voltage Tolerance & Class F Insulation

The LBBE(RT)320-PT-02 backward curved centrifugal fan accepts a wide input voltage range of AC380–480V, adapting seamlessly to voltage fluctuations in rail transit power networks across different regions and routes. With Class F insulation, the motor withstands elevated operating temperatures under sustained heavy load while maintaining stable insulation performance. This industrial EC blower operates reliably across an ambient temperature range of -25℃ to +60℃, coping with both frigid winter conditions and high-temperature summer environments. Its S1 continuous duty rating supports non-stop long-term running for onboard cooling systems without thermal derating.

5. Maintenance-Free Operation & Global Compliance

Fitted with high-precision sealed ball bearings, this rail transit centrifugal fan runs completely maintenance-free over its entire service life, eliminating the need for periodic lubrication and reducing field maintenance workload for rail operators. Standardized mounting dimensions simplify installation and replacement of the backward curved centrifugal fan inside inverter cabinets, minimizing equipment downtime during servicing. All units comply with CE, RoHS, ISO and BSCI international standards, ensuring safety, environmental compatibility and consistent build quality for rail transit projects worldwide.

Product Overview

Product Overview

Application Scenarios

  • Subway Auxiliary Inverter Cooling: As a dedicated thermal solution for metro auxiliary inverters, this EC backward curved centrifugal fan delivers continuous high-pressure airflow to exhaust heat from power electronic modules, keeping inverter systems stable across all load conditions. It is the standard matching centrifugal blower for urban rail transit auxiliary power systems.
  • Onboard Rail Transit Ventilation: This industrial centrifugal blower is widely deployed for ventilation and heat dissipation in urban rail transit passenger carriages, driver cabs and equipment compartments, maintaining air quality and protecting onboard electrical devices from overheating during long-distance operation.
  • Railway Electrical Cabinet Cooling: The backward inclined EC fan is ideal for cooling various onboard electrical enclosures, including traction converters, control cabinets and power distribution boxes, delivering targeted airflow to critical heat-generating components and extending equipment service life.
  • Ground-Side Rail Transit Equipment: This IP55/IP44 EC fan also serves ground-based rail facilities such as platform screen door systems, signal equipment rooms and station ventilation units, providing reliable cooling performance in semi-outdoor and industrial environments with dust and moisture exposure.

Frequently Asked Questions

Q: What is the minimum order quantity for this rail transit fan? A: The MOQ for the LBBE(RT)320-PT-02 backward curved centrifugal fan is 1 unit for sample testing. Volume-based discounts are available for bulk wholesale and project orders.

Q: Can this EC fan be customized for specific protection grade or connector requirements? A: Yes, we offer customization on protection grade (IP55/IP44), speed curve, connector type and mounting configuration to fit different rail transit equipment specifications and OEM demands.

Q: What is the standard delivery lead time? A: Standard ready-to-ship models are delivered within 7–15 working days. Customized configurations require 15–25 working days depending on specification complexity.

LBBE(RT)320-PT-02 EC Backward Curved Centrifugal Fan for Rail Transit

Optimized for subway auxiliary inverter heat dissipation, this industrial centrifugal blower features DC stepless speed regulation, dual IP55/IP44 protection ratings, Class F insulation and rugged all-metal construction.

Request a Quote

Featured Products

lbbert320 pt 02 ec backward curved centrifugal fan for rail transit-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000