D2D160-DE02-11 D2D160-CE02-11 D2D160-BE02-11 D2D160-BE02-12 D2D160-BE02-14 Fans

Turbine Centrifugal Fan Series for Industrial Cooling: Five D2D160 models deliver controlled airflow for cabinets, machinery enclosures, and long-distance air delivery.

Dual Inlet and Dual Outlet Airflow Structure: Multi-channel intake and directional outlet paths support concentrated airflow in confined equipment and ventilation systems.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain stable operation during continuous-duty applications.

Wide Electrical and Temperature Coverage: Single- or three-phase, 230V/400V, 50/60Hz operation and -25°C to +90°C conditions support varied industrial installations.

Request a Quote
  • Overview

Overview

Product Summary

The D2D160 Centrifugal Fan series is intended for industrial cooling, equipment ventilation, cabinet airflow, and applications that require controlled air delivery through a defined path. The family includes D2D160-DE02-11, D2D160-CE02-11, D2D160-BE02-11, D2D160-BE02-12, and D2D160-BE02-14. Selection should begin with the complete part reference, technical documentation, and verified requirements of the installed equipment.

A D2D160 Centrifugal Fan uses a turbine-style impeller to draw air through side intake channels and direct it toward outlet openings. This arrangement can be evaluated where air must travel through a cabinet, machine enclosure, ventilation passage, filter, duct, or other route that creates resistance. The final airflow depends on the complete installation, not on the fan assembly alone.

img-mrykcimy-90972cdc.png

Basic Description & Engineering Overview

The D2D160 Centrifugal Fan family includes single-phase and three-phase options, 230V and 400V supply coverage, and 50Hz or 60Hz compatibility. The stated family operating range is 2700–2960 RPM, with 700–1055W power and 460–560Pa pressure. These values apply across the series and must not be assigned to every individual reference without checking the relevant technical sheet.

The D2D160 Centrifugal Fan series uses a permanent-magnet brushless outer rotor motor with pure copper windings and imported precision bearing support. The outer rotor arrangement integrates the rotating motor section with the fan assembly to provide a compact layout for controlled airflow. Exact electrical, mechanical, and performance values remain dependent on the selected reference.

Correct reference identification is the first step in selecting a D2D160 Centrifugal Fan. Similar-looking units can differ in phase, voltage, connection arrangement, mounting details, inlet profile, outlet orientation, or operating requirements. Comparing only visible dimensions or a general product category is not enough to confirm that a unit is suitable for a replacement or new installation.

For replacement work, compare the installed label with the complete candidate reference. For new equipment, compare the proposed D2D160 Centrifugal Fan with the required electrical supply, mounting interface, available clearance, inlet and outlet geometry, airflow route, and service access. This documentation-based approach supports reliable maintenance sourcing and engineering review.

7 (1).jpg

Key Features & Technical Advantages

A D2D160 Centrifugal Fan works with the complete route connected to its inlet and outlet. Filters, ducts, protective guards, narrow openings, cable routing, internal partitions, and nearby components can all create resistance. A clear intake and correctly positioned outlet help air move through the intended cooling path rather than remain in restricted areas.

Before fitting a D2D160 Centrifugal Fan, inspect the intake side, outlet side, mounting position, available installation space, protective arrangement, and maintenance access. If a filter is blocked, a duct is narrow, a guard is restrictive, or an outlet is poorly positioned, the available pressure may be used before air reaches the target area. Include these conditions in selection planning.

The D2D160 Centrifugal Fan range includes 230V and 400V family supply options for single-phase or three-phase installations. Confirm the required phase, voltage, frequency, and connection arrangement against documentation for the exact selected reference. Family-level electrical coverage is useful for initial review, but it does not replace model-specific confirmation before ordering or installation.

Mechanical review should include mounting-hole positions, installation thickness, inlet and outlet profile, connection location, available clearance, and service access. A unit that fits one cabinet may not fit another where the duct route, panel opening, wiring layout, or surrounding equipment is different. Use applicable CAD drawings before final selection.

The D2D160 Centrifugal Fan family uses a brushless outer rotor motor with pure copper windings and precision bearing support. The turbine impeller directs air from the intake toward the outlet route through the housing. This configuration can be evaluated for equipment requiring directional air movement through a defined path.

Exact pressure, speed, power, and installation data must remain tied to the full model reference. A final D2D160 Centrifugal Fan selection should be based on verified system resistance, electrical requirements, mounting conditions, and the technical data that applies to the selected unit.

img-mryjxnzz-c91bd73b.png

Technical Specifications
Item Confirmed information
Product type D2D160 Centrifugal Fan family
Model references DE02-11, CE02-11, BE02-11, BE02-12, and BE02-14
Electrical options Single-phase / three-phase; 230V / 400V
Frequency 50/60Hz
Series speed range 2700–2960 RPM
Family power range 700–1055W
Family pressure range 460–560Pa
Operating temperature -25°C to +90°C
Motor construction Brushless outer rotor motor with pure copper windings
Compliance CE series-level documentation
Technical Documentation & Installation Planning

Technical parameter sheets, performance curves, wiring diagrams, and CAD dimensional drawings support D2D160 Centrifugal Fan selection. These materials help engineering and purchasing teams review supply requirements, mounting space, airflow direction, installation thickness, inlet and outlet geometry, and ventilation resistance before purchasing or replacing a unit.

Use the available documentation to confirm the exact D2D160 Centrifugal Fan reference before a final decision. Documentation-based review is important when related models look similar but have different electrical, mounting, connection, or airflow requirements. Keep relevant materials available for installation and maintenance work.

Industry Applications

A D2D160 Centrifugal Fan may be evaluated for electrical cabinets, automation equipment, industrial machine housings, commercial kitchen ventilation, factory or office air circulation, compatible forced-air systems, tunnels, underground areas, and suitable agricultural or industrial facilities. In every application, the selected reference should match verified supply, mounting layout, airflow direction, and equipment requirements.

For enclosed equipment, a D2D160 Centrifugal Fan can support controlled air movement where there is a defined route from intake to outlet. The final review should account for filters, ducts, guards, cable routing, internal partitions, and heat-producing components. These conditions influence the final operating point after the equipment is assembled.

Commercial Value & Selection Support
  1. Identify the complete D2D160 Centrifugal Fan reference.
  2. Compare the label with applicable technical documentation.
  3. Verify the required phase, voltage, frequency, and connection arrangement.
  4. Review mounting position, inlet profile, outlet direction, and available clearance.
  5. Check filters, ducts, guards, cable routing, and other ventilation restrictions.
  6. Use technical data and CAD drawings before final selection.
Expert Insights: Managing Centrifugal Airflow Resistance

A D2D160 Centrifugal Fan should be evaluated as part of the full system rather than as an isolated component. Filters, ducts, narrow openings, protective guards, cable routing, and internal partitions can consume available pressure before air reaches the intended cooling area.

During design or maintenance, review the inlet condition, outlet direction, mounting orientation, nearby components, and service access. Compare the completed layout with applicable performance data and technical documentation before final selection.

img-mehj7k-94f326ab.png

FAQ

What is a D2D160 Centrifugal Fan used for?
A D2D160 Centrifugal Fan can be evaluated for compatible equipment cooling, cabinet ventilation, machinery airflow, and installations requiring controlled air movement through a defined route.

Which models are included?
The series includes D2D160-DE02-11, D2D160-CE02-11, D2D160-BE02-11, D2D160-BE02-12, and D2D160-BE02-14.

What should be confirmed before ordering?
Confirm the complete model reference, phase and voltage requirement, frequency, mounting layout, inlet and outlet direction, operating environment, and applicable technical documentation.

D2D160-DE02-11 D2D160-CE02-11 D2D160-BE02-11 D2D160-BE02-12 D2D160-BE02-14 Fans

Turbine Centrifugal Fan Series for Industrial Cooling: Five D2D160 models deliver controlled airflow for cabinets, machinery enclosures, and long-distance air delivery.

Dual Inlet and Dual Outlet Airflow Structure: Multi-channel intake and directional outlet paths support concentrated airflow in confined equipment and ventilation systems.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain stable operation during continuous-duty applications.

Wide Electrical and Temperature Coverage: Single- or three-phase, 230V/400V, 50/60Hz operation and -25°C to +90°C conditions support varied industrial installations.