120mm Single Inlet Centrifugal Fan Series: Four G2E120 AR77 and CR21 models support controlled airflow for cabinets, equipment enclosures, and industrial ventilation.
Durable Galvanized Steel and Die-Cast Aluminum Construction: A steel impeller and aluminum housing support robust mechanical integration for industrial equipment.
IP44 and Class B Insulation Series: IEC, EN, CE, and CCC compliance references support engineering selection and equipment documentation.
Wide Environmental Coverage for Equipment Cooling: Horizontal-shaft installation, internal thermal overload protection, and -40°C to +80°C conditions support varied industrial applications.
The G2E120 Centrifugal Fan range is intended for equipment ventilation, electrical cabinet cooling, machine enclosures, and controlled industrial airflow. The listed references are G2E120-AR77-01, G2E120-CR21-01, G2E120-AR77-23, and G2E120-CR21-13. Selection should begin with the complete model reference, the equipment layout, and the technical documentation that applies to the selected unit.
A G2E120 Centrifugal Fan draws air through one side of the impeller and guides it toward an outlet path. This single-inlet arrangement can be evaluated for cabinets, enclosures, ventilation channels, and air passages where the system creates resistance. The final result depends on the complete intake and outlet route rather than the fan alone.

The G2E120 Centrifugal Fan family uses a 120mm hot-dip galvanized steel impeller and a die-cast aluminum alloy housing. The confirmed unit weight is 1.97kg. The assembly is specified for clockwise rotation when viewed from above and horizontal-shaft installation. These family-level details should be checked against the required equipment layout before installation.
The series is specified with IP44 protection subject to installation method, Class B insulation, and an internal TOP thermal overload protector. The stated environmental information includes a maximum ambient operating temperature of +80°C and a storage and transport low-temperature limit of -40°C. Review actual operating and installation conditions before selecting a reference.
Correct reference identification is the first step in selecting a G2E120 Centrifugal Fan. Similar-looking AR77 and CR21 units can differ in mounting details, connection arrangement, rotation direction, airflow requirement, or equipment compatibility. Comparing only the fan outline or the general family name is not enough to establish a suitable replacement.
For replacement work, compare the installed label with the complete candidate reference. For new equipment, compare the proposed G2E120 Centrifugal Fan with the mounting position, horizontal-shaft arrangement, available clearance, inlet and outlet profile, rotation direction, connection area, and service access. This documentation-based review supports accurate maintenance and procurement decisions.
A G2E120 Centrifugal Fan works with the complete ventilation route connected to it. Air enters through the single inlet side and is directed by the impeller toward the outlet. A clear intake path and a properly positioned outlet support controlled air movement through compatible equipment. Filters, grills, guards, ducts, cable bundles, and internal partitions can all add resistance.
Before fitting a G2E120 Centrifugal Fan, inspect the mounting position, available installation space, inlet and outlet profile, guard arrangement, cable routing, nearby components, and maintenance access. Restricted filters, narrow passages, or poorly positioned internal parts can reduce the airflow available at the intended equipment area.
The G2E120 Centrifugal Fan family uses a 120mm galvanized steel impeller and a die-cast aluminum alloy housing. These confirmed materials form the stated mechanical structure. The specified clockwise rotation should be confirmed during mounting, because the required orientation affects the intended inlet and outlet relationship in the equipment.
Mechanical review should include the mounting interface, installation thickness, mounting-hole positions, horizontal-shaft orientation, inlet and outlet opening, available clearance, and service access. A unit that fits one cabinet may not fit another where the panel layout, guard position, internal wiring, or surrounding equipment is different.

| Item | Confirmed information |
|---|---|
| Product type | AC G2E120 Centrifugal Fan family |
| Listed references | AR77-01, CR21-01, AR77-23, and CR21-13 |
| Unit weight | 1.97kg |
| Impeller diameter | 120mm |
| Impeller material | Hot-dip galvanized steel sheet |
| Housing material | Die-cast aluminum alloy |
| Rotation direction | Clockwise when viewed from above |
| Installation | Horizontal shaft |
| Protection rating | IP44, subject to installation method |
| Insulation class | Class B |
| Motor protection | Internal TOP thermal overload protector |
A G2E120 Centrifugal Fan may be evaluated for electrical cabinets, automation equipment, machine housings, compatible ventilation assemblies, control panels, commercial kitchen ventilation, factory or office air circulation, and suitable forced-air systems. In every application, the selected reference should match verified mounting, rotation, airflow, and equipment requirements.
For enclosed equipment, a G2E120 Centrifugal Fan can support controlled air movement where there is a defined route from intake to outlet. The final selection review should account for filters, guards, ducts, cable routing, internal partitions, and components that produce heat. These conditions influence system resistance in the completed installation.

CAD dimensional drawings and technical parameter information support G2E120 Centrifugal Fan selection. These resources help teams review fan outline, installation thickness, mounting-hole positions, inlet and outlet profiles, connection area, available equipment space, and horizontal-shaft installation requirements before purchasing or replacing a unit.
Use available documentation to confirm the exact G2E120 Centrifugal Fan reference before ordering, replacing, or installing a unit. Documentation-based review is particularly important when several AR77 and CR21 models appear similar but have different mounting or equipment requirements. Keep relevant technical information available for installation and maintenance work.
The G2E120 Centrifugal Fan is specified with IP44 protection subject to the installation method. Review the actual enclosure, protective arrangement, and operating environment before using this rating in an equipment design. Class B insulation and the internal TOP thermal overload protector are confirmed series features that should be considered with the required operating conditions.
The maximum ambient operating temperature is stated as +80°C, while the storage and transport low-temperature limit is -40°C. These values should be compared with the actual equipment environment. IEC 60990, EN 60335-1, CE, and CCC are stated as series-level compliance references. Confirm the selected model and installation conditions for documentation work.

What is a G2E120 Centrifugal Fan used for?
A G2E120 Centrifugal Fan can be evaluated for compatible equipment ventilation, electrical cabinet cooling, machine enclosures, and installations requiring controlled airflow through a defined route.
Which references are included?
The listing includes G2E120-AR77-01, G2E120-CR21-01, G2E120-AR77-23, and G2E120-CR21-13.
What should be confirmed before ordering?
Confirm the complete reference, mounting position, clockwise rotation, equipment opening, installation conditions, required airflow path, and applicable technical documentation.
120mm Single Inlet Centrifugal Fan Series: Four G2E120 AR77 and CR21 models support controlled airflow for cabinets, equipment enclosures, and industrial ventilation.
Durable Galvanized Steel and Die-Cast Aluminum Construction: A steel impeller and aluminum housing support robust mechanical integration for industrial equipment.
IP44 and Class B Insulation Series: IEC, EN, CE, and CCC compliance references support engineering selection and equipment documentation.
Wide Environmental Coverage for Equipment Cooling: Horizontal-shaft installation, internal thermal overload protection, and -40°C to +80°C conditions support varied industrial applications.