190mm energy-saving EC backward curved centrifugal fan with PA66 impeller, IP55/IP54, 639m³/h for equipment room and workshop ventilation.
Industrial Ventilation Fans | EC Centrifugal Blowers for Equipment Rooms
The LBBE3G190-072NS-14 is an energy-efficient EC backward curved centrifugal fan designed for equipment room ventilation and workshop heat dissipation applications. Built with a durable PA66 engineering plastic impeller and precision ball bearings, this industrial centrifugal blower delivers 639 m³/h maximum airflow at 2940 r/min with only 64W rated power. Available with optional IP55 or IP54 protection ratings, Class F high-temperature insulation and S1 continuous duty operation, it runs reliably across an ambient temperature range of -25℃ to +60℃. As the low-power base model in a three-variant 190mm series, it offers a cost-effective, low-noise ventilation solution for server rooms, electrical equipment cabinets and light industrial spaces.
| Model | Power | Speed | Air Flow |
| LBBE3G190-072NS-14 | 64W | 2940 r/min | 639m³/h |
| LBBE3G190-072NS-15 | 135W | 3700 r/min | 855m³/h |
| LBBE3G190-072NS-16 | 104W | 4230 r/min | 851m³/h |




This EC backward curved centrifugal fan features a precision-molded PA66 engineering plastic impeller with an optimized backward-inclined blade profile. Running at a moderate 2940 r/min, the backward curved blade structure generates stable static pressure with minimal air turbulence, delivering consistent airflow for equipment room ventilation without excessive power draw. PA66 material offers excellent mechanical toughness, heat resistance and anti-aging performance, ensuring long-term structural stability under continuous daily operation. The aerodynamically tuned blade geometry also keeps operating noise at a comfortable level, making this backward curved centrifugal fan well suited for installation in and around server rooms and electrical equipment spaces where noise control is critical.
This 190mm EC centrifugal fan series includes three distinct performance variants to match different ventilation load requirements. The LBBE3G190-072NS-14 base model uses 64W to push 639 m³/h at 2940 r/min, ideal for small equipment rooms and light-duty workshop air exchange. The LBBE3G190-072NS-15 steps up to 135W, 3700 r/min and 855 m³/h for larger factory floor ventilation. The LBBE3G190-072NS-16 provides 104W at 4230 r/min with 851 m³/h for higher-pressure duct and cabinet cooling applications. System designers can right-size the industrial centrifugal blower to actual room volume, duct resistance and heat load, avoiding over-specification and unnecessary energy cost.
Equipped with Class F motor insulation, this low-power EC centrifugal blower withstands elevated temperature rise under sustained load while retaining stable insulation properties. It operates reliably across a wide ambient temperature range from -25℃ to +60℃, adapting to both cold-season unheated equipment rooms and summer production areas where ambient temperatures can climb significantly. The 230V 50/60Hz dual-frequency power input ensures compatibility with commercial power grids across different regions, supporting export ventilation projects worldwide. Its S1 continuous duty rating permits 24/7 non-stop running, which is essential for always-on equipment room and server cooling.


Offered in both IP55 and IP54 protection grades, this backward curved centrifugal fan can be selected according to the dust and moisture level of the installation site. The fully sealed motor housing blocks dust ingress and resists water splashes, protecting internal windings and bearings from particulate contamination commonly found in factory workshops and semi-outdoor equipment spaces. IP55 is recommended for dusty production areas and outdoor-adjacent duct connections, while IP54 suits protected indoor server room and cabinet installations. This flexible protection approach extends service life and reduces maintenance interventions in demanding industrial environments.
Fitted with high-precision sealed ball bearings, this backward curved centrifugal fan runs completely maintenance-free across its service life, eliminating scheduled lubrication and reducing on-site upkeep for facility managers. The compact, standardized mounting footprint simplifies installation inside equipment cabinets, ventilation units or ductwork, and facilitates straightforward replacement of older fans during retrofit projects. All units carry CE, RoHS, ETL, BSCI, CCC and ISO certifications, confirming compliance with international safety, energy efficiency and environmental standards for industrial and commercial ventilation markets.
Q: What is the difference between NS-14, NS-15 and NS-16? A: NS-14 is the 64W / 2940 r/min / 639 m³/h low-power base model for equipment rooms; NS-15 is the 135W / 3700 r/min / 855 m³/h high-flow version for factory ventilation; NS-16 is the 104W / 4230 r/min / 851 m³/h higher-speed option for duct and cabinet cooling.
Q: Can I choose between IP55 and IP54 protection? A: Yes, both protection grades are available. IP55 offers stronger dust and splash protection for harsh workshop environments, while IP54 is suitable for cleaner indoor equipment room installations. Please specify your requirement when ordering.
Q: Is this fan suitable for continuous 24-hour operation in a server room? A: Yes, it is rated S1 continuous duty. It is designed for non-stop long-duration running under rated conditions, making it ideal for always-on equipment room cooling, server ventilation and round-the-clock industrial ventilation applications.