LBBE3G250-102PS-06 EC backward curved centrifugal turbine fan, aluminum alloy impeller, IP55/IP44, 2472m³/h at 520W for workshop exhaust.
The LBBE3G250-102PS-06 is a high-power EC backward curved centrifugal fan built for industrial workshop ventilation, fume exhaust and high-resistance ductwork. Fitted with an aluminum alloy impeller on a brushless EC motor, this backward curved centrifugal fan moves 2472 m³/h at 3650 r/min on 520W shaft power, delivering the static pressure needed to push air through long ducts, grease baffles and filter media in large exhaust systems. The assembly carries IP55/IP44 sealing, Class F/B insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, and runs on a wide 400V/230V/115V 50/60Hz supply. As the first and lowest-output model of this seven-variant 250mm PS/PT family, this backward curved centrif
ugal fan bridges standard workshop exhaust and kitchen fume extraction, while the remaining six models scale output up to 1000W and 3708 m³/h.
| Model | Power | Speed | Air Flow |
| LBBE3G250-102PS-06 | 520W | 3650 r/min | 2472m³/h |
| LBBE3G250-102PS-07 | 750W | 4100r/min | 3039m³/h |
| LBBE3G250-102PT-08 | 1000W | 3860 r/min | 3708m³/h |
| LBBE3G250-092PS-20 | 145W | 2500 r/min | 1730m³/h |
| LBBE3G250-102PS-22 | 240W | 3150 r/min | 1524m³/h |
| LBBE3G250-102PS-23 | 270W | 3170 r/min | 1751m³/h |
| LBBE3G250-102PS-24 | 370W | 3500 r/min | 1700m³/h |
This backward curved centrifugal fan runs at speeds a plastic rotor could not sustain for long, so its impeller is cast and stamped from aluminum alloy rather than engineering plastic. The backward-inclined turbine blade path turns motor rotation into static pressure rather than free velocity, which is what lets this backward curved centrifugal fan hold 2472 m³/h against the resistance of long exhaust ducts and filter stages. The metal rotor resists heat distortion, grease buildup and abrasive factory dust, and its added rotating mass damps vibration at 3650 r/min, reducing the structure-borne noise that reaches adjacent rooms. Because the impeller does not creep under centrifugal stress, blade clearance in the volute stays constant across years of service.
The power core of this backward curved centrifugal fan is a brushless EC motor rated at 520W, sized to deliver high-pressure airflow without the inefficiency of a belt-driven blower. The electronically commutated drive keeps its efficiency at partial speed, so this backward curved centrifugal fan can be slowed during light-load shifts instead of throttled with a damper, where much of the fan energy would simply be wasted as pressure loss. Speed is steplessly adjustable, allowing the exhaust controller to ramp the backward curved centrifugal fan up as heat and fume load rise and settle it back after peak production. Soft-start current limiting also protects the factory power feed and contactor from startup surge.





The family is offered in two sealing levels, and this exhaust centrifugal blower can be matched to its mounting zone rather than over-sealed. IP55 blocks fine dust ingress and resists water splashing from any direction for dusty workshop floors, greasy kitchen lines and chemical handling areas; IP44 suits protected indoor housings and ducted cabinets where only coarse dust and light splash are expected. The sealed motor housing keeps grease mist and particulate away from windings and bearings, so this backward curved centrifugal fan keeps performance stable where an open-frame blower would grind down in a matter of months.
Winding insulation is Class F/B, giving this backward curved centrifugal fan thermal reserve for sustained high-power load, an important margin when a 520W motor sits inside an exhaust plenum that traps its own heat. The -25℃ to +60℃ ambient window covers cold unheated plants, warm summer workshops and hot cooking zones without derating. Rated for 400V, 230V and 115V at 50/60Hz, this backward curved centrifugal fan matches three common supply architectures, so one SKU can ship into European three-phase sites, 230V commercial premises and North American 115V installations without a custom motor.
All seven models in this family keep a 3 kg frame and 250mm impeller envelope, so the same duct collar and mounting interface can serve every power level. The 102PS-06 backward curved centrifugal fan at 520W and 2472 m³/h covers workshop and kitchen exhaust; the 102PS-07 reaches 3039 m³/h at 750W; the 102PT-08 tops the range at 1000W and 3708 m³/h. Downstream, the 092PS-20 at 145W and 1730 m³/h handles light kitchen duty, the 102PS-22 at 240W and 1524 m³/h and 102PS-23 at 270W and 1751 m³/h serve AC exhaust, and the 102PS-24 at 370W and 1700 m³/h handles chemical-area ventilation. Sealed ball bearings run maintenance-free, and every unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification.




Q: Is 2472 m³/h enough for a large workshop exhaust system? A: This backward curved centrifugal fan delivers 2472 m³/h at 3650 r/min on 520W, suitable for medium workshop and kitchen exhaust with moderate duct resistance. For longer ducts or heavier loads, the 102PS-07 reaches 3039 m³/h and the 102PT-08 reaches 3708 m³/h.
Q: What voltages does this fan support? A: The rated supply is 400V/230V/115V at 50/60Hz, so this backward curved centrifugal fan can serve three-phase European sites, 230V commercial grids and 115V North American installations without a separate motor variant.
Q: Can speed be adjusted and is continuous operation allowed? A: Yes to both. The EC motor supports stepless speed regulation, and the unit is S1 continuous duty with sealed ball bearings, built for non-stop running within the -25℃ to +60℃ ambient range.
LBBE3G250-102PS-06 EC backward curved centrifugal turbine fan, aluminum alloy impeller, IP55/IP44, 2472m³/h at 520W for workshop exhaust.