LBBE3G280-092NS-12 external rotor EC backward curved centrifugal fan, galvanized impeller, IP54/IP44, 1813m³/h at 165W, speed adjustable for factory ventilation.
The LBBE3G280-092NS-12 is a 280mm DC brushless external rotor EC backward curved centrifugal fan built for factory workshop ventilation and heat dissipation. Mounting a galvanized sheet impeller on an external rotor EC motor, this backward curved centrifugal fan delivers 1813 m³/h at 2600 r/min on 165W shaft power, with step less speed adjustment to match real workshop heat load. The assembly carries IP54/IP44 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 230V 50/60Hz. As the entry model of this four-variant 280mm f amily, this backward curved centrifugal fan covers standard factory air exchange, while the remaining three variants scale output from 190W up to 1100W and airflow to 4378 m³/h for heavy industrial exhaust.
| Model | Power | Speed | Air Flow |
| LBBE3G280-092NS-12 | 165W | 2600 r/min | 1813m³/h |
| LBBE3G280-092NS-13 | 190W | 2200 r/min | 1743 m³/h |
| LBBE3G280-102NT-17 | 1100W | 3370 r/min | 4378 m³/h |
| LBBE3G280-102NS-19 | 625W | 3000 r/min | 3039 m³/h |
The core of this backward curved centrifugal fan is a 280mm galvanized sheet impeller with a backward-inclined blade path. Galvanized sheet resists rust and corrosion better than plain steel in humid or dusty factory air, and the formed blade profile holds its geometry under centrifugal load at 2600 r/min. The backward curved design converts motor rotation into static pressure rather than free velocity, so this backward curved centrifugal fan keeps 1813 m³/h moving against duct elbows and filter screens instead of losing throughput once resistance rises. The metal impeller also tolerates occasional abrasive dust in production airstreams, and its balanced rotor keeps vibration and outlet turbulence low enough for installation near occupied work areas.
This backward curved centrifugal fan uses an external rotor DC brushless EC motor, where the magnet ring rotates around the stationary stator hub. That architecture removes belt and pulley losses, delivers high torque at low speed, and frees the motor center for the impeller mounting, keeping the whole assembly compact at 3 kg. The EC drive supports stepless speed regulation, so a workshop controller can ramp the backward curved centrifugal fan up as machine heat rises and settle it back during light shifts, instead of running at fixed speed and wasting energy through dampers. Brushless operation also means no commutator wear, extending service life in daily industrial duty.




Offered in IP54 or IP44 protection grades, this factory centrifugal blower can be matched to its installation zone rather than over-sealed. The IP54 build blocks fine dust ingress and resists splashing water for dusty production floors and semi-outdoor plant rooms; the IP44 option suits protected indoor cabinet and ducted installations where only coarse dust is present. The sealed motor housing keeps particulate away from windings and ball bearings, so this backward curved centrifugal fan holds performance steady where an open-frame blower would collect grit and drift in output over time.
Class F winding insulation gives this backward curved centrifugal fan thermal headroom under sustained full-load operation, which matters when the motor sits inside a ventilation plenum that traps its own heat. The rated -25℃ to +60℃ ambient range covers cold unheated workshops, warm summer production floors and seasonal plant-room temperature swings without derating. S1 duty confirms this backward curved centrifugal fan is built for non-stop continuous operation rather than intermittent short bursts, and the 230V 50/60Hz input matches standard commercial grids for export factory ventilation projects.
All four models in this family keep a 3 kg frame and 280mm impeller envelope, so one duct collar and mounting interface can serve every power level. The 092NS-12 backward curved centrifugal fan at 165W and 1813 m³/h covers standard workshop air exchange; the 092NS-13 at 190W and 1743 m³/h serves lighter factory duty; the 102NS-19 at 625W and 3039 m³/h handles heavier exhaust; the 102NT-17 at 1100W and 4378 m³/h covers high-volume industrial ventilation. Sealed ball bearings run without a relubrication schedule, and every unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, giving a single backward curved centrifugal fan platform across light and heavy factory applications.




Q: What airflow does the 092NS-12 deliver? A: This backward curved centrifugal fan delivers 1813 m³/h at 2600 r/min with 165W shaft power, suited to standard factory workshop ventilation and general heat dissipation.
Q: Is the speed adjustable? A: Yes. The external rotor EC brushless motor supports stepless speed regulation, so this backward curved centrifugal fan can be trimmed to actual heat and airflow load instead of running at a fixed full speed.
Q: How does it compare with the other 280mm variants? A: The 092NS-13 gives 1743 m³/h at 190W; the 102NS-19 gives 3039 m³/h at 625W; the 102NT-17 gives 4378 m³/h at 1100W. All four share the 280mm galvanized impeller, 3 kg frame and S1 continuous duty rating.
LBBE3G280-092NS-12 external rotor EC backward curved centrifugal fan, galvanized impeller, IP54/IP44, 1813m³/h at 165W, speed adjustable for factory ventilation.