Next-Gen EC Motor Innovation: Utilizes clever electronic commutation inside the EC backward-curved centrifugal fan to pull way less power than traditional fixed-speed AC setups.
If you have been hunting around for a dependable, energy-saving thermal management fix, you can stop looking right here because the LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan is built to handle the toughest operational jobs. In today’s high-demand industrial setups and commercial facilities, hardware overheating can easily cause unexpected shut-downs and eat right into your bottom line. That is exactly why system builders and facility engineers constantly hunt for a high-performance EC backward-curved centrifugal fan that brings together modern electronic commutation technology, heavy-duty 380V/400V grid adaptability, and elite structural integrity.
This specific model pairs an aerodynamically fine-tuned aluminum alloy impeller with advanced, smooth variable speed modulation. Whether you are overhauling a massive data center cooling framework, optimizing a sprawling commercial HVAC network, or designing high-precision medical diagnostic equipment, this heavy-duty 380V industrial fan delivers incredible airflow stability alongside serious power savings. As a direct factory maker powered by Guangdong Lebisen Fan Co., Ltd, we keep warehouse stock across multiple specifications so we can ship fast. On top of that, we provide fully tailored OEM and ODM modification services so you can seamlessly drop this unit right into your own proprietary systems. Backed by solid international credentials like ISO, BSCI, and CE, plus deep bulk quantity discounts, our LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan gives your business the exact market edge it needs to stay ahead of the competition.











Let us pull back the housing and look at what makes this machine tick under the hood. Engineered specifically for continuous, round-the-clock operations, the LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan runs smoothly on robust electrical systems, making it a fantastic drop-in swap for heavy industrial machinery. The centerpiece of the unit is its dynamically balanced aluminum alloy impeller, carefully sculpted to slash air turbulence, quiet down aerodynamic noise levels, and drive up static pressure efficiency.
Unlike old-school AC blowers that just run at one fixed speed, the built-in EC motor technology inside this EC backward-curved centrifugal fan lets you tap into smooth external speed control using basic operational signals. This means your equipment can automatically ramp airflow up or down based on real-time thermal demands, which cuts out massive amounts of wasted energy and stretches out the service life of the internal motor components.
Furthermore, we outfitted this 380V industrial fan with premium, long-lasting ball bearings and rated it for an S1 continuous working cycle. That means it can run 24/7, even at ambient temperatures from -25℃ up to +60℃. Protected by an IP54 or IP44 rating against blowing dust and moisture ingress, and wrapped tightly in Class F insulation materials, this rugged 400V centrifugal fan handles gritty factory floors just as comfortably as clean, climate-controlled server rooms.




Next-Gen EC Motor Innovation: Utilizes clever electronic commutation inside the EC backward-curved centrifugal fan to pull way less power than traditional fixed-speed AC setups.
Robust 380V/400V Power Capacity: Engineered to integrate into heavy commercial and industrial power grids.
Aerodynamic Impeller Architecture: Built from top-grade, lightweight aluminum alloy to ensure ultra-smooth air passage and fantastic static pressure output.
Non-Stop S1 Duty Cycle: Engineered for continuous 24/7 runtime, guaranteeing this 380V industrial fan never leaves you hanging during peak workloads.
Tough Environmental Shielding: Solid IP54/IP44 weather and dust defense combined with Class F thermal insulation, making this 400V centrifugal fan survive harsh conditions.
Flexible Custom OEM Support: Need special wiring harnesses, unique mounting adjustments or custom voltages? Our factory team handles custom builds to your drawings.
| Item | Specification Details |
| Product Model | LBBE3G450‑188NT‑16 (Variants: LWBE3G500‑138NT‑13 / LWBE3G500‑188NT‑14) |
| Product Type | EC Backward‑Curved Centrifugal Fan |
| Impeller Material | High-Grade Aluminum Alloy |
| Bearing System | Heavy-Duty Ball Bearing |
| Operation Mode | S1 (Continuous Duty) |
| Protection Class | IP54 / IP44 |
| Insulation Class | Class F |
| Operating Temperature | -25℃ ~ +60℃ |
| Rated Voltage | 380V / 400V, 50/60Hz |
| Certificates | ISO, BSCI, CE |
For a clear picture of what these units achieve in service, see the certified ratings of the matching models:
LWBE3G500‑138NT‑13: Operates on 400V with a power consumption of 870W and a current draw of 1.46A. It delivers a powerful airflow of 8137 cubic meters per hour, a static pressure peak of 464 Pa, spinning at 1100 RPM with an acoustic noise profile of just 71 dB(A).
LWBE3G500‑188NT‑14: A higher-output variant drawing 2400W at 4.9A under 400V power. It pushes an immense airflow volume of 10305 cubic meters per hour against a static pressure of 903 Pa at 1705 RPM, maintaining an acoustic rating of 76 dB(A).
When mapping out complex thermal layouts, choosing the right air-moving hardware is everything. Traditional backward-curved blowers driven by standard AC induction motors tend to lose efficiency fast when you throttle them down to partial loads. Conversely, the smart internal inverter board sitting inside the LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan constantly tweaks the stator magnetic fields. This slashes slip losses to a minimum, keeping motor efficiency remarkably high across a very broad speed spectrum.
Mechanically speaking, going with aluminum alloy for the impeller on this 380V industrial fan gives you an awesome strength-to-weight ratio. Lower rotational mass puts way less mechanical wear and tear on the internal ball bearings when the fan spins up, which stretches your maintenance schedules out much further.
Additionally, looking closer at the thermal engineering side, Class F insulation means the internal copper wire windings can safely withstand heat loads up to 155℃. This provides a generous safety cushion when the 400V centrifugal fan gets pushed hard near its +60℃ ambient cap. By combining smart electronic regulation with bulletproof mechanical design, this LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan helps facility managers chop their total lifecycle ownership costs way down.
Because of its adaptability, engineers across many sectors frequently specify the LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan for their core builds:
Ventilation & Air-Conditioning: Boosts fresh air exchange and distribution efficiency in large commercial and industrial air handling boxes.
Data-Center Cooling: Delivers dependable, high-static-pressure cooling for high-density server racks, power distribution units, and UPS battery rooms using this 380V industrial fan.
Refrigeration Units & Cabinets: Maintains stable, even sub-zero temperatures inside large industrial walk-in freezers and commercial food storage warehouses.
Medical Equipment & Cleanrooms: Provides clean, tightly regulated airflow for sensitive healthcare testing gear and clean laboratory environments.
Rail Transit & Transportation: Cools down onboard electrical traction inverters, power management cabinets, and passenger vehicle climate control units.
Drive Equipment & Mechanical Systems: Keeps automated assembly lines, high-powered machinery, and factory heating systems from overheating with this 400V centrifugal fan.
Sourcing your ventilation parts directly through Guangdong Lebisen Fan Co., Ltd gives your firm an immediate edge in the global marketplace. As an established, professional manufacturer focusing heavily on HVACR ventilation gear, we keep massive warehouse stocks across multiple specifications ready for immediate dispatch, keeping project timelines safe from supply chain delays.
Furthermore, our direct-factory pricing structure rewards large-scale buyers with steep volume discounts, letting you drive down hardware costs while actually upgrading your build quality. Every single EC backward-curved centrifugal fan rolling off our lines undergoes tough factory testing to make sure it clears international benchmarks like ISO, BSCI, and CE. Whether you need a massive bulk stock shipment or a custom OEM prototype built from scratch, our technical crews and regional office supports (including local hubs in Russia and Poland) are ready to back you up.
Q1: Why should I switch over from an older AC fan to an EC backward-curved centrifugal fan?
A: An EC backward-curved centrifugal fan brings built-in electronic speed controls and much higher electrical efficiency to the table. It uses way less power at partial speeds, runs significantly quieter, and hooks right into smart automation networks.
Q2: What are the primary performance differences between the listed models?
A: The LWBE3G500-138NT-13 delivers 8137 cubic meters per hour at 870W, while the LWBE3G500-188NT-14 ramps up to 2400W for over 10,300 cubic meters per hour in demanding 380V industrial fan applications.
Q3: What kind of quality certifications do these industrial cooling fans carry?
A: Every single LBBE3G450-188NT-16 380V EC backward-curved centrifugal fan is built under strict factory quality standards and holds full ISO, BSCI, and CE credentials for smooth global importing.


Next-Gen EC Motor Innovation: Utilizes clever electronic commutation inside the EC backward-curved centrifugal fan to pull way less power than traditional fixed-speed AC setups.