The LOBISONG LB12025 is a 120×120×25mm brushless DC axial fan engineered for quiet, efficient cooling in large enclosures. Its wide impeller delivers strong airflow, ideal for PCs, server racks, power supplies, inverters, LED drivers, and telecom cabinets.
LOBISONG LB12025 is a 120 × 120 × 25mm brushless DC fan engineered for quiet, efficient cooling in large enclosures. Its wide impeller delivers 60 to 110 CFM from roughly 1,200 to 2,500 RPM, and the DC fan stays between 22 and 38 dBA while doing it. Offered in 12V, 24V and 48V with two-wire, tach or PWM connections, the DC fan carries dual ball bearings rated for 50,000 hours and a PBT body moulded to UL 94V-0. Auto-restart and polarity protection complete the package.


The paragraph below is the LB12025 description taken from the LOBISONG sheet, unchanged. What follows explains how this DC fan gets its volume without turning noisy, and where it fits in a modern cabinet.
LOBISONG LB12025 120×120×25mm DC Fan — High Airflow, Low Noise
The LOBISONG LB12025 is a 120×120×25mm brushless DC axial fan engineered for quiet, efficient cooling in large enclosures. Its wide impeller delivers strong airflow, ideal for PCs, server racks, power supplies, inverters, LED drivers, and telecom cabinets.
Available in 12V, 24V, and 48V DC, with 2-wire, 3-wire tach, and 4-wire PWM options. Dual ball bearings provide stable rotation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy; auto-restart and polarity protection ensure safety.
Key specs: 120×120×25mm; 12/24/48V; speed ~1,200–2,500 RPM; airflow ~60–110 CFM; noise 22–38 dBA; static pressure up to ~0.15 in H₂O; operating temp −20°C to +65°C. Easy to integrate, the LB12025 keeps systems cool and reliable.
A wide impeller moves more air per revolution than a narrow one, and that single fact drives the design of this DC fan. Because each turn of the DC fan sweeps a larger disc of air, the motor can run slowly and still meet the duty, which is why the sound pressure of the DC fan stays inside an office-friendly band. Slow rotation also spreads bearing wear over more hours, so the wear-out life of the DC fan stretches further than a smaller unit working at double the speed to reach the same figure.
The 25mm depth keeps the DC fan relevant in modern equipment, where chassis are built around slim switch-mode supplies and stacked drive cages. Wiring options are deliberately wide: a two-wire build suits a simple device, a tach wire lets a controller watch the DC fan, and a PWM lead allows the DC fan to follow system load. Between 12V, 24V and 48V variants, the DC fan covers appliance, automation and telecom hardware without a separate frame size for each rail.
Up to 110 CFM Airflow – The wide sweep of the DC fan shifts serious volume, which lets one unit ventilate a cabinet that once required two smaller units and their wiring.
22 dBA at Low Speed – Turned down, the DC fan is nearly inaudible from a metre away, so equipment can share a room with the people who operate it.
50,000 Hour Ball Bearings – Continuous industrial duty belongs to the ball version of the DC fan, whose races hold clearance through heat and vibration.
Wide Voltage Coverage – 12V, 24V and 48V builds share one chassis, so the same DC fan serves bench equipment, mobile machinery and telecom racks.
Three Wiring Styles – Two-wire, three-wire and four-wire options let the DC fan slot into an existing harness or report its speed to a control board.
Flame-Retardant Materials – PBT frame and impeller rated UL 94V-0 keep the DC fan acceptable inside power supplies and other regulated products.
| Technical Parameter | Specification Value |
| Product Type | 120mm DC Axial Fan |
| Model Number | LB12025 |
| Frame Size | 120 × 120 × 25 mm |
| Rated Voltage | 12V / 24V / 48V DC |
| Speed Range | 1,200–2,500 RPM |
| Airflow | 60–110 CFM |
| Static Pressure | 0.15 in H₂O max. |
| Noise Level | 22–38 dBA |
| Lead Options | 2-wire, 3-wire tach, 4-wire PWM |
| Life Expectancy | Up to 50,000 hours |
| Bearings | Ball bearings |
| Material | PBT 7 fan blade |
| Motor life | 50000 hours |
| Insulation level | Class A |
| Working temperature | -20℃~60℃ |
| Weight | 121.3g |
Volume ratings deserve a second look before a designer commits. Free-air figures compare DC fan models fairly on a test stand, yet a cabinet is not a test stand: grills, cables and heatsink fins all subtract from the number. The saving grace of a large DC fan is that it starts with so much margin that even a substantial loss leaves a useful working point. A 120mm DC fan that begins at 110 CFM can lose a third of its volume to obstructions and still cool an enclosure that a smaller unit would leave hot.
Mechanical fit decides the rest. The square frame matches the hole pattern shared by most equipment in this class, so service teams can carry one spare DC fan for several machine types, and a failed unit is swapped rather than rebuilt. For an operator balancing uptime against inventory, a standard 120mm DC fan is the cheapest insurance in the cabinet.
Typical duties for this DC fan:
Slim equipment, large air demand and quiet operation rarely appear together, yet that is exactly the brief for this DC fan. LOBISONG supplies the unit across all three voltages and can send samples for acoustic and thermal testing on the machine itself.


One DC fan replacing two is the simplest saving in the cabinet, and it repeats on every unit a manufacturer ships. Fewer units mean fewer leads, fewer mounting points and fewer parts to keep in stock, and a regulator-approved frame keeps certification clean. The 22 dBA figure also has a price: equipment that can be sited in a showroom, a clinic or an office opens markets where a loud machine cannot go. LOBISONG builds the DC fan in its own facility and can prepare OEM versions with custom harnesses, speed curves and branding.
How much air does the DC fan move at its lowest speed?
Enough for idle electronics. Most cabinets need only a fraction of the peak figure once steady state is reached, which is why the DC fan spends its life at reduced speed.
Can two DC fan units be mounted in series?
They can, and stacking them raises pressure. Mount both in the same direction of flow, and drive them from one controller so the pair behaves as a single DC fan.
Is the DC fan suitable for dusty workshops?
With a filter on the inlet the DC fan copes with workshop air. Clean or replace the media on schedule so the DC fan is not asked to work against a blind filter.

The LOBISONG LB12025 is a 120×120×25mm brushless DC axial fan engineered for quiet, efficient cooling in large enclosures. Its wide impeller delivers strong airflow, ideal for PCs, server racks, power supplies, inverters, LED drivers, and telecom cabinets.