The LOBISONG LB15050 is a 150×150×50mm brushless DC axial fan engineered for high-volume airflow and strong static pressure. Its large impeller and deep 50mm frame move air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, and industrial control panels.
LOBISONG LB15050 is a 150 × 150 × 50mm brushless DC fan engineered for high-volume airflow and strong static pressure at low rotational speed. The large impeller sweeps 150 to 300 CFM through dense heatsinks, filters and ducted enclosures, while the 50mm frame gives the DC fan room to work against real resistance. Versions run on 12V, 24V or 48V with two-wire, tach or PWM connections, and the DC fan carries dual ball bearings rated to 60,000 hours, a PBT UL 94V-0 body and protection against miswiring.


The description below comes straight from the LOBISONG sheet for the LB15050 and is quoted without change. The following notes explain why a large DC fan turning slowly often outlasts a small one turning fast.
LOBISONG LB15050 150×150×50mm DC Fan — Powerful Large-Format Cooling
The LOBISONG LB15050 is a 150×150×50mm brushless DC axial fan engineered for high-volume airflow and strong static pressure. Its large impeller and deep 50mm frame move air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, and industrial control panels.
Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM control. Dual ball bearings deliver stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection.
Key specs: 150×150×50mm; 12/24/48V; airflow ~150–300 CFM; noise 35–55 dBA; temp −20°C to +65°C. Reliable cooling for critical systems.
Rotational speed is the quiet tax on fan life. Bearings wear with revolutions, so a big DC fan that turns at half the speed of a small one accumulates its wear more slowly while moving the same air. That arithmetic is why large equipment tends to use this class of DC fan: the impeller does the work, the motor stays relaxed, and the acoustic profile of the DC fan settles into a low hum that disappears into the background of a telecom site or a factory floor. The 50mm housing also gives the blade a generous sweep without asking for a large opening, so the panel cut stays practical.
At this size, the DC fan brings something smaller units cannot: real airflow through a long duct. Telecom outdoor cabinets, industrial control panels and power conversion equipment all push air through filters, mesh and silencers before it reaches the electronics, and a large impeller starts with enough volume that a long path does not empty its curve. Because the DC fan is built in three voltage versions with tach and PWM leads, it drops into DC plant, battery-backed equipment or a simple 12V service cabinet without re-engineering the mounting.
150–300 CFM Sweep – A wide impeller gives the DC fan the volume to ventilate a full enclosure, not just the hot corner nearest the grill.
Lagging Speed, Long Life – Fewer revolutions per minute mean the bearings of the DC fan accumulate wear more slowly, which is how the unit reaches its 60,000-hour life.
50mm Deep Housing – Depth gives the impeller of the DC fan a working angle that holds pressure, so mesh and silencers do not stall the DC fan.
Low Audible Signature – The tone of the DC fan sits low in the spectrum, which is the band people tolerate in workshops, plant rooms and service buildings.
Flexible Control – Two-wire, tach and PWM builds let the DC fan run simply or report its speed to a monitoring panel.
Safety-Rated Construction – PBT frame and impeller rated UL 94V-0 keep the DC fan compliant inside power conversion cabinets that undergo inspection.
| Technical Parameter | Specification Value |
| Product Type | 150mm High-Volume DC Axial Fan |
| Model Number | LB15050 |
| Frame Size | 150 × 150 × 50 mm |
| Rated Voltage | 12V / 24V / 48V DC |
| Airflow | 150–300 CFM |
| Static Pressure | Strong static pressure build |
| Noise Level | 35–55 dBA |
| Lead Options | 2-wire, 3-wire tach, 4-wire PWM |
| Life Expectancy | Up to 60,000 hours |
| Bearings | Ball bearings |
| Material | PBT 5 fan blade |
| Motor life | 50000 hours |
| Insulation level | Class A |
| Working temperature | -20℃~60℃ |
| Weight | 700g |
Airflow ratings scale with the cube of impeller diameter when speed is fixed, which is why a 150mm DC fan can match the output of a 92mm unit drawing more power and making more noise. The practical result is a cooling system that spends less energy for the same result, easing the load the DC fan puts on the power supply. In battery-backed installations, that difference shows up as longer autonomy, and the DC fan becomes part of the efficiency story rather than an afterthought.
Mechanical stability matters at this size too. A 150mm impeller carries real momentum, so the frame of the DC fan is ribbed to hold its shape and the motor is mounted on a machined boss rather than a pressed spider. That structure keeps the tip clearance even over years of service, which protects both the airflow of the DC fan and the acoustics that made it suitable in the first place.

Where a large low-speed DC fan suits the building:
When the heat load is measured in kilowatts rather than watts, this is the class of DC fan that keeps the cabinet calm. LOBISONG supplies the unit across all three voltages and can provide performance data or samples for cabinets that will be tested as a system.


Operators buy this DC fan to stop buying replacements. A slow-turning, large impeller keeps its bearings cool and its speed steady for the best part of a decade, which removes the annual fan swap from the maintenance calendar. Energy use falls at the same time, and because the DC fan is quieter, cabinets can be sited where people work instead of behind a locked door. Because the DC fan comes out of the LOBISONG factory, pricing also stays stable across a multi-year programme, with customised speed curves and private labels available.
Why choose a 150mm DC fan over a smaller unit?
Airflow per decibel and per watt. The larger DC fan matches the output of a smaller model while turning slower, which lengthens bearing life and lowers noise.
Does the DC fan need a filter to protect it?
A coarse inlet filter keeps dust off the blades and lets the DC fan hold its balance. Choose a media grade that does not strangle the airflow the DC fan needs.
Can the DC fan be run continuously at 48V?
Yes. The 48V build is a production variant, not an experiment, and the DC fan is rated for continuous duty within its working temperature window.

The LOBISONG LB15050 is a 150×150×50mm brushless DC axial fan engineered for high-volume airflow and strong static pressure. Its large impeller and deep 50mm frame move air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, and industrial control panels.