LOBISONG DC Fan LB17250 172×150×51mm

The LOBISONG LB17250 is a 172×150×51mm brushless DC axial fan built for powerful, high-volume airflow. Its large impeller and deep 51mm frame move air through dense heatsinks, filters, and ducted enclosures, ideal for servers, telecom cabinets, power supplies, inverters, and industrial control panels.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

LOBISONG LB17250 is a 172 × 150 × 51mm brushless DC fan built for powerful, high-volume airflow in equipment that cannot rely on a square frame. Its large impeller drives 180 to 350 CFM against a pressure ceiling near 0.50 in H₂O across a 1,500 to 3,500 RPM window. The DC fan runs from 12V, 24V or 48V and accepts two-wire, tach or PWM leads, while dual ball bearings support 60,000 hours of service. The 51mm housing keeps the DC fan effective behind grills, mesh and fin stacks.

image.pngimage.png

Detailed Product Description & Technical Deep Dive

The LB17250 entry from the LOBISONG sheet appears below in full and unedited. The discussion after it covers rack cooling, rectifier shelves and the practical reasons this rectangular DC fan still holds its place.

LOBISONG LB17250 172×150×51mm DC Fan — High-Volume Cooling

The LOBISONG LB17250 is a 172×150×51mm brushless DC axial fan built for powerful, high-volume airflow. Its large impeller and deep 51mm frame move air through dense heatsinks, filters, and ducted enclosures, ideal for servers, telecom cabinets, power supplies, inverters, and industrial control panels.

Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM. Dual ball bearings ensure stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection.

Key specs: 172×150×51mm; 12/24/48V; speed ~1,500–3,500 RPM; airflow ~180–350 CFM; static pressure up to ~0.50 in H₂O; noise 40–58 dBA; temp −20°C to +65°C. Choose LOBISONG LB17250 for dependable high-volume cooling.

Rectangular mounting is a legacy of the equipment this size evolved inside. Rectifier shelves, telecom racks and industrial power frames were built around a 172 by 150mm opening long before square fans became common, and the machines in service today still expect that footprint. This DC fan keeps the format alive with modern electronics: the same cutout that once held a mains-driven blower now accepts a brushless unit, which is why so many retrofit projects end with the DC fan bolted into an existing plate rather than with a new chassis.

Performance at this size suits equipment that dissipates serious heat. A rectifier bank or an inverter stack presents dense aluminium fins and long air paths, and the DC fan has the volume to clear them without running at its maximum. That reserve matters in summer, when the difference between the rated figure and the working figure separates a comfortable cabinet from a thermal trip. Tach and PWM options let the site monitor the DC fan and vary its speed with load, which keeps noise down at night when the demand curve drops and the DC fan can idle.

Key Features & Benefits

172 × 150mm Retrofit Frame – The rectangular pattern matches legacy blower openings, so the modern DC fan replaces older units without touching the cabinet sheet metal.

180–350 CFM Output – Volume is delivered across a wide speed window, giving integrators room to trade airflow against acoustics as the site demands.

0.50 in H₂O Pressure Head – Finned rectifier stacks and long air paths set up resistance, and the DC fan answers with pressure rather than raw speed.

Three Voltage Options – 12V, 24V and 48V versions let the DC fan serve vehicle equipment, telecom plant and industrial control from one design.

Speed and Tach Signals – A PWM build allows the DC fan to follow load, and the tach wire gives a panel a live confirmation that the DC fan is turning.

Long-Life Ball Bearings – Races selected for continuous industrial duty keep the DC fan within specification for 60,000 hours.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 172mm High-Volume DC Axial Fan
Model Number LB17250
Frame Size 172 × 150 × 51 mm
Rated Voltage 12V / 24V / 48V DC
Speed Range 1,500–3,500 RPM
Airflow 180–350 CFM
Static Pressure 0.50 in H₂O max.
Noise Level 40–58 dBA
Lead Options 2-wire, 3-wire tach, 4-wire PWM
Life Expectancy Up to 60,000 hours
Bearings Ball bearings
Material PBT 5 fan blade
Motor life 50000 hours
Insulation level Class A
Working temperature -20℃~60℃
Weight 655g
Engineering Advantages & Professional Analysis

Rack cooling has a habit of being designed once and modified forever. Trays are added, cards are upgraded, and the heat load creeps upward until the original airflow is no longer enough. Because this DC fan uses the legacy opening, capacity can be restored without new fabrication: a higher speed build of the DC fan, or a second unit in series, lifts the working point without a new plate. Sites that plan for growth find the DC fan absorbs the first two rounds of expansion on its own.

Durability is the other consideration at this size. A 51mm deep impeller carries real inertia, so the DC fan uses a balanced moulding and a shaft supported by preloaded races. The result is a DC fan that tolerates the vibration of a busy equipment room and holds its airflow over a decade of service, which is precisely the horizon over which telecom and power operators measure their cooling assets.

image.png

Target Applications

Duties where the rectangular DC fan fits straight in:

  • Telecom racks and rectifier shelves: the DC fan replaces legacy blowers without a change of plate.
  • Server and switch cabinets: the DC fan shifts the volume that stacked trays demand.
  • Inverter and UPS frames: the DC fan clears heavy fin stacks in power conversion equipment.
  • Industrial control panels: the DC fan holds a large enclosure at a stable temperature.
  • Battery rooms and power plants: the DC fan keeps air moving across racks of stored energy.

Legacy openings and modern electronics keep this DC fan on the specification list year after year. LOBISONG supplies the DC fan in all three voltages and can provide dimensional drawings or samples before a retrofit goes ahead.

image.pngimage(4a1e3932f8).png

Commercial Value & B2B ROI

Retrofit work is priced in labour hours, and a DC fan that matches the existing opening removes most of them. No plate drilling, no new gaskets, no re-certification of the enclosure: the DC fan arrives, the old unit leaves, and the cabinet goes back into service the same day. A DC fan that bolts straight in also shortens the outage window, since the swap is measured in minutes. The savings compound across a fleet of racks, which is why operators standardise their spares around one DC fan and one set of leads, and why LOBISONG keeps OEM channels open for private labels and custom harnesses.

Frequently Asked Questions (FAQ)

Will this DC fan fit an old 172mm blower opening?
In most cases yes. Drawing dimensions should be checked, but the frame and hole pattern were kept compatible with the legacy blowers this DC fan succeeds.

How much noise should a site expect?
Between 40 and 58 dBA depending on build and speed. Operators who monitor load through a PWM channel usually run the DC fan well below the top of that band.

Can the DC fan be repaired in the field?
It is designed for replacement rather than repair. Swap the DC fan, return the old DC fan to the depot, and keep the airflow path on schedule without workshop time.

image(dcbc0496bd).pngimage(5d87b78bf7).png

LOBISONG DC Fan LB17250 172×150×51mm

The LOBISONG LB17250 is a 172×150×51mm brushless DC axial fan built for powerful, high-volume airflow. Its large impeller and deep 51mm frame move air through dense heatsinks, filters, and ducted enclosures, ideal for servers, telecom cabinets, power supplies, inverters, and industrial control panels.

Request a Quote

Featured Products

lobisong dc fan lb17250 17215051mm-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000