The LOBISONG LB22060 is a 220×60mm brushless DC axial fan engineered for high-volume airflow in large enclosures. Its oversized impeller and 60mm deep frame move air through dense heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.
LOBISONG LB22060 is a 220 × 60mm brushless DC fan engineered for high-volume airflow in large enclosures where depth is limited. Its oversized impeller moves 400 to 800 CFM across speeds of 800 to 2,200 RPM, with pressure reaching 0.65 in H₂O. The DC fan carries a die-cast aluminium frame, UL-listed lead wire and Class B insulation, works between −10℃ and 70℃, and is offered in 12V, 24V and 48V builds with tach or PWM wiring.


The LOBISONG sheet description of the LB22060 is repeated below word for word. The notes after it deal with the trade this DC fan makes: a large diameter inside a shallow body.
LOBISONG LB22060 220×60mm DC Fan — High-Volume Cooling
The LOBISONG LB22060 is a 220×60mm brushless DC axial fan engineered for high-volume airflow in large enclosures. Its oversized impeller and 60mm deep frame move air through dense heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.
Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM control. Dual ball bearings ensure stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection.
Key specs: 220×60mm; 12/24/48V; speed ~800–2,200 RPM; airflow ~400–800 CFM; static pressure up to ~0.65 in H₂O; noise 45–68 dBA; temp −20°C to +65°C. Choose LOBISONG LB22060 for powerful, dependable cooling.
Depth is often the constraint that decides a ventilation scheme. Doors, walkways and roof edges leave only a narrow space behind a panel, and a deep fan cannot be fitted without rebuilding the structure around it. A large diameter solves the airflow problem without adding depth: the impeller of this DC fan sweeps a wide disc, so a modest rotational speed produces the volume a big enclosure needs. The DC fan slides into a shallow plenum and leaves the walkway clear, which is the practical reason this format survives in plant design.
The vent opening matters as much as the fan. To move eight hundred cubic feet a minute, the DC fan needs somewhere for the air to enter and leave, and an inlet that is too small will starve it regardless of the specification printed on the label. Designers pairing this DC fan with louvres or a ceiling grille usually size the opening so the face velocity stays reasonable, and the aluminium frame gives the DC fan the rigidity to sit flat against a panel that may not be perfectly true.
400–800 CFM Airflow – Volume for large halls, cabinets and plant rooms, produced by a DC fan that is only 60mm deep.
0.65 in H₂O Pressure Head – The DC fan holds its working point behind louvres, mesh and filters that would otherwise cut its output.
Shallow 60mm Profile – A slim body lets the DC fan mount on doors and in plenums where deeper units simply do not fit.
Aluminium Frame – The DC fan keeps its shape under vibration, and the frame also helps move heat away from the motor.
UL Wiring and Class B – Recognised lead wire and Class B insulation help the DC fan pass electrical inspection without additional work.
Speed and Tach Signals – A controller can trim the speed of the DC fan with load, or read its tach output to confirm rotation.
| Technical Parameter | Specification Value |
| Product Type | %%220mm High-Volume DC Axial Fan |
| Model Number | LB22060 |
| Frame Size | 220 × 220 × 60 mm |
| Rated Voltage | 12V / 24V / 48V DC |
| Speed Range | 800–2,200 RPM |
| Airflow | 400–800 CFM |
| Static Pressure | 0.65 in H₂O max. |
| Noise Level | 45–68 dBA |
| Lead Options | 2-wire, 3-wire tach, 4-wire PWM |
| Life Expectancy | Up to 50,000 hours |
| Bearings | Ball bearings |
| Material | Impeller: Plastic; Frame: Aluminum Alloy |
| Lead Wire | UL Type |
| Insulation level | Class B |
| Working temperature | -10℃~70℃ |
| Weight | 1350g |
Airflow per watt improves as diameter grows, and this DC fan takes full advantage of the rule. Turning slowly with a wide blade, the DC fan reaches a volume that a smaller unit could only match by spinning quickly, which raises noise, current and wear together. For a plant that runs its ventilation year round, that difference shows up in the energy bill, and for a maintenance team it shows up in how rarely the DC fan needs attention.
Structural honesty is the second half of the story. A 220mm impeller carries inertia, and the DC fan frame has to hold the motor precisely while the blade turns. The die-cast housing on this DC fan does that without flexing, so the clearance between blade tip and shroud stays uniform, airflow stays stable, and the unit does not develop the pulsing tone that a distorted frame produces. That is the engineering behind the warranty: the DC fan is not just bigger, it is truer.

Duties that suit a wide, shallow DC fan:
Shallow structures and big volumes normally fight each other; a wide, slow DC fan resolves the argument. LOBISONG supplies the DC fan in all three voltages, and guards, filters and grilles can be quoted with the DC fan so the opening is sized before delivery.


Plant engineers value a DC fan that solves a room problem with one opening instead of several. Fewer units mean fewer maintenance points, and a slow-turning impeller means fewer of those points will need attention during the life of the building. Energy consumption tracks the same logic: moving air gently costs less than moving it quickly, and the DC fan was designed around that principle. LOBISONG manufactures the DC fan in house and supports plant and HVAC contractors with drawings, performance data and delivery schedules that match the construction programme.
Can the DC fan be mounted on a door?
Yes. The shallow body and aluminium frame suit door mounting, provided the door structure can take the weight and the DC fan is guarded on both sides.
How large should the inlet be?
As a rule of thumb, keep the free area generous relative to the DC fan volume. Undersized openings raise velocity and noise while reducing the airflow the DC fan can deliver.
Does the DC fan come with speed control?
A PWM build follows a controller signal. Sites without a controller use the two-wire version, which runs at its rated speed as soon as power is applied.

The LOBISONG LB22060 is a 220×60mm brushless DC axial fan engineered for high-volume airflow in large enclosures. Its oversized impeller and 60mm deep frame move air through dense heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.