lobisong-dc-fan-lb22580-22522580mm993, lobisong-dc-fan-lb22580-22522580mm993, /dc-cooling-fan
Inquiry
Inquiry

LOBISONG DC Fan LB22580 225×225×80mm

The LOBISONG LK22580 is a 225×225×80mm brushless DC axial fan built for extreme airflow and high static pressure. Its oversized impeller and deep 80mm frame move massive air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, HVAC systems, and industrial control panels.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

LOBISONG LB22580 is a 225 × 225 × 80mm brushless DC fan built for extreme airflow and high static pressure. The oversized impeller and deep frame move 500 to 900 CFM through dense heatsinks, filters and ducted enclosures at 800 to 2,000 RPM, with pressure reaching 0.80 in H₂O. A high-torque motor drives the DC fan on 12V, 24V or 48V, ball bearings carry a 50,000-hour rating, and the aluminium frame with UL-listed leads suits industrial cabinets that are inspected and audited.

LOBISONG DC Fan LB22580 225×225×80mm

LOBISONG DC Fan LB22580 225×225×80mm

Detailed Product Description & Technical Deep Dive

The catalogue text for this model is reproduced below without alteration, including its original model spelling. The notes that follow describe where the largest DC fan in the range belongs, and what commissioning a DC fan of this size involves.

LOBISONG LK22580 225×225×80mm DC Fan — Extreme High-Pressure Cooling

The LOBISONG LK22580 is a 225×225×80mm brushless DC axial fan built for extreme airflow and high static pressure. Its oversized impeller and deep 80mm frame move massive air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, HVAC systems, and industrial control panels.

Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM control. Dual ball bearings ensure stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection. Its robust construction and high-torque motor ensure reliable performance in demanding environments.

Key specs: 225×225×80mm; 12/24/48V; speed ~800–2,000 RPM; airflow ~500–900 CFM; static pressure up to ~0.80 in H₂O; noise 50–70 dBA; temp −20°C to +65°C. Choose LOBISONG LK22580 for powerful, dependable high-pressure cooling.

At the top of a fan range, the engineering problem changes shape. The 225mm impeller in its 80mm housing gives the DC fan the swept area and the pressure head to clear a battery of filters and a metre of duct without losing its working point, and that combination is what industrial plants need when a machine, a room or an exhaust path has to be ventilated reliably. The high-torque motor starts the DC fan against that resistance rather than stalling, and the aluminium frame of the DC fan holds the assembly steady while the impeller turns.

Commissioning benefits from a few minutes of care. Airflow direction is marked on the housing, and the DC fan should be bolted to a stiffened surface so that panel resonance does not amplify the blade pass tone. Speed of the DC fan can be trimmed with a PWM signal to match the duty, and the tach output gives the maintenance team a live signal to watch. Where a plant pairs two of these units, one on supply and one on extract, the DC fan pair should share a controller so the two run at the same working point.

Key Features & Benefits

500–900 CFM Output – The largest DC fan in the range moves enough air to ventilate a heavy enclosure or a small plant room on its own.

0.80 in H₂O Pressure – Ducts, louvres and loaded filters all subtract from airflow, and the pressure head of this DC fan keeps a usable margin behind them.

High-Torque Motor – Starting against resistance is the normal condition for this DC fan, so the motor is sized for the load rather than the free-air case.

Aluminium Housing – A cast frame gives the DC fan the rigidity that an impeller of this size needs to keep tip clearance stable.

Industrial Wiring – UL-listed lead wire and Class B insulation let the DC fan meet the documentation requirements of industrial projects.

Monitorable Operation – PWM and tach connections turn the DC fan into a managed part of the ventilation system rather than an unattended accessory.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 225mm High-Pressure DC Axial Fan
Model Number LB22580
Frame Size 225 × 225 × 80 mm
Rated Voltage 12V / 24V / 48V DC
Speed Range 800–2,000 RPM
Airflow 500–900 CFM
Static Pressure 0.80 in H₂O max.
Noise Level 50–70 dBA
Lead Options 2-wire, 3-wire tach, 4-wire PWM
Life Expectancy Up to 50,000 hours
Bearings Ball bearings
Material Impeller: Plastic; Frame: Aluminum Alloy
Lead Wire UL Type
Insulation level Class B
Working temperature -10℃~70℃
Weight 2000g
Engineering Advantages & Professional Analysis

Ventilating a machine is not the same as ventilating a room. A machine cabinet has internal obstacles, a defined inlet and a defined outlet, and its airflow path is short enough that pressure drop dominates the calculation. This DC fan is engineered for exactly that condition, with a pressure ceiling that allows real ducting and filtering to sit in the path. The reward is measured in reliability: components inside the machine see stable air temperature, and the DC fan does not need to run at full speed to hold that condition.

Service planning matters at this size too. Bearings rated for fifty thousand hours push the first intervention beyond the normal warranty cycle, and the standard mounting pattern means a replacement DC fan arrives as a direct swap rather than a fabrication project. Spares for the DC fan can be held centrally and fitted by any competent technician, which keeps large sites independent of specialist contractors and shortens the average repair window.

LOBISONG DC Fan LB22580 225×225×80mm

Target Applications

Where the largest DC fan in the series is used:

  • Industrial exhaust paths: the DC fan draws fumes and warm air from machines with ducted outlets.
  • Battery and rectifier rooms: the DC fan keeps large DC plant within temperature limits.
  • HVAC and air handling equipment: the DC fan drives air through coils and filter banks.
  • Containerised plant and skids: the DC fan provides ventilation where space is fixed by the ISO frame.
  • Workshops with high heat loads: the DC fan exchanges air across welding, cutting and coating areas.

When a project reaches the point where nothing smaller will do, this DC fan is the one that holds the duty. LOBISONG supplies the DC fan across three voltages and can provide mounting details, performance data and sample units for engineers who need the DC fan proven before the system is signed off.

LOBISONG DC Fan LB22580 225×225×80mm details

Commercial Value & B2B ROI

Industrial ventilation is a capital decision with a long tail of running costs, and a large DC fan affects both ends of it. The purchase price covers a DC fan that outlasts several maintenance cycles, while the operating cost reflects a slow impeller drawing modest current for its output. Fewer units also mean fewer spares, fewer panel penetrations and less cabling, all of which show up on the project budget. LOBISONG builds the DC fan in its own factory and supports contractors with submittal documents, warranty terms and delivery schedules aligned to the installation programme.

image.pngimage(4a1e3932f8).png

Frequently Asked Questions (FAQ)

Can the DC fan discharge into a duct?
The DC fan can discharge into a duct; keep the run short and the bends gentle, and size the duct so that the DC fan is not fighting a restriction it cannot see.

How much current does the DC fan draw at 48V?
The exact figure depends on the speed build. LOBISONG supplies a current curve with each order so the DC fan can be matched to the supply and its protection.

Is a soft start needed with this DC fan?
Not normally, because the motor ramps itself. If a site shares a limited supply, a PWM controller can limit the inrush of the DC fan at start-up.

image(5d87b78bf7).pngimage(dcbc0496bd).png

LOBISONG DC Fan LB22580 225×225×80mm

The LOBISONG LK22580 is a 225×225×80mm brushless DC axial fan built for extreme airflow and high static pressure. Its oversized impeller and deep 80mm frame move massive air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, HVAC systems, and industrial control panels.

Request a Quote

Featured Products

lobisong dc fan lb22580 22522580mm993-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000