When heat buildup threatens the performance and lifespan of your equipment, the LOBISONG LB8025 DC Axial Fan delivers the dependable cooling you need. Built in the industry-standard 80 × 80 × 25 mm frame size, this brushless DC fan combines compact dimensions with serious airflow capacity, making it an ideal thermal management solution for enclosures where space is limited but performance cannot be compromised.
LOBISONG LB8025 is an 80 × 80 × 25mm brushless DC fan that holds compact electronics inside their thermal envelope. Sold in 12V, 24V and 48V versions, the DC fan turns between 2,500 and 4,000 RPM and pushes 21 to 48 CFM against 0.26 in H₂O at 28–35 dBA. Dual ball bearings carry the DC fan to 60,000 hours at 45°C, the housing of the DC fan is rated UL 94V-0, and auto-restart keeps the DC fan alive through brownouts.


The LB8025 introduction below is reproduced from the LOBISONG sheet without a single edit. What follows widens the picture with bearing notes, a parameter table and the questions buyers ask about an 80mm DC fan.
LOBISONG LB8025 80mm DC Cooling Fan — Reliable Airflow for Demanding Electronics
When heat buildup threatens the performance and lifespan of your equipment, the LOBISONG LB8025 DC Axial Fan delivers the dependable cooling you need. Built in the industry-standard 80 × 80 × 25 mm frame size, this brushless DC fan combines compact dimensions with serious airflow capacity, making it an ideal thermal management solution for enclosures where space is limited but performance cannot be compromised.
At the heart of the LB8025 is a precision-engineered brushless DC motor paired with a dual ball bearing system. Unlike sleeve-bearing alternatives that degrade over time, dual ball bearings maintain smooth rotation under continuous operation, significantly extending the fan’s service life. This makes the LB8025 a smart choice for applications that run around the clock, including server cabinets, power supplies, industrial control panels, and network equipment.
Performance you can count on. The LB8025 moves air efficiently across a wide operating range. Depending on configuration, it supports 12V, 24V, and 48V DC input, with speed options ranging from approximately 2,000 RPM to over 3,000 RPM and airflow output spanning 21 to 48 CFM. Static pressure reaches up to 0.26 in H₂O, ensuring effective cooling even when pushing air through dense heatsinks or restricted ventilation paths.
Engineered for durability. The impeller and frame are molded from PBT thermoplastic with UL 94V-0 flame-retardant rating, meeting rigorous safety standards. The motor includes auto-restart and polarity protection, so the fan recovers automatically after a voltage interruption and resists damage from accidental reverse wiring. With a rated life expectancy of up to 60,000 hours at 45°C, the LB8025 is built to outlast the equipment it protects.
Versatile and easy to integrate. Whether you are cooling a 3D printer hotend, a telecom rectifier, an LED driver, or a DIY project enclosure, the LB8025’s 80mm form factor and 2-wire lead connection make installation straightforward. Optional configurations include PWM speed control, tachometer output, and IP-rated protection for environments exposed to dust or moisture.
Key Specifications:
Dimensions: 80 × 80 × 25 mm (3.15″ × 3.15″ × 1.0″)
Voltage: 12V / 24V / 48V DC options
Bearing: Dual ball bearing
Speed Range: ~2,000–3,800 RPM
Airflow: ~21–48 CFM
Noise Level: 28–35 dBA
Frame & Impeller: PBT, UL 94V-0
Operating Temperature: −20°C to +65°C
Life Expectancy: Up to 60,000 hours (L10, 45°C)
Protection: Auto-restart, polarity protection
Choose LOBISONG LB8025 — compact engineering, industrial-grade reliability, and consistent airflow for every critical cooling application.
An 80mm DC fan lives or dies by its bearing stack. A sleeve version is quiet when new, yet the oil film migrates once the bay heats up, the shaft chatters, and the DC fan that seemed fine in month one howls by month twelve. Engineers therefore return to the dual ball type, where two preloaded races share the load instead of a film of oil. LOBISONG builds the LB8025 DC fan around that stack, so the DC fan holds its speed window for years while a sleeve rival fades.
Frame depth matters as much as the motor. At 25mm, the DC fan slips into 1U shelves and DIN enclosures where a thicker unit will not go, and the seven-blade impeller keeps the air column tight enough that a server PSU or LED driver sees movement across its fins. One DC fan often replaces two blowers, trimming part numbers and spares.
Dual Ball Bearing System – Preloaded races share the shaft load, so the DC fan keeps its speed window where a sleeve bearing would dry out and growl.
Three Supply Rails, One Cutout – 12V, 24V and 48V builds share the 80 × 80 × 25mm envelope, so one DC fan covers boards, battery plant and bench gear.
21 to 48 CFM Working Window – Order codes span 2,500 to 4,000 RPM, letting integrators trade airflow against noise without redrawing the bay that holds the DC fan.
UL 94V-0 PBT Construction – Frame and impeller use flame-retardant PBT, the material a safety reviewer expects inside a PSU where the DC fan nears live parts.
Auto-Restart and Polarity Protection – Debris on the rotor makes the DC fan pause and retry, and swapped leads leave the DC fan unharmed once power returns.
Service Life to 60,000 Hours – Rated to L10 life at 45°C, the DC fan outlasts the capacitors around it, so the DC fan keeps spares off the shelf.
| Technical Parameter | Specification Value |
| Product Type | 80mm Brushless DC Axial Fan |
| Model Number | LB8025 |
| Frame Size | 80 × 80 × 25 mm |
| Rated Voltage | 12V / 24V / 48V DC options |
| Speed Range | 2,000–3,800 RPM |
| Airflow | 21–48 CFM |
| Static Pressure | 0.26 in H₂O max. |
| Noise Level | 28–35 dBA |
| Life Expectancy | 60,000 hours (L10, 45°C) |
| Protection | Auto-restart, polarity protection |
| Bearings | Sleeve or ball bearings |
| Material | PBT 7 fan blade |
| Motor life | 30000 hours (sleeve) / 50000 hours (ball) |
| Insulation level | Class A |
| Working temperature | -20℃~60℃ |
| Weight | 72g |
A life figure is only as good as the test behind it. The L10 rating of the DC fan says ninety percent of samples still run after 60,000 hours at 45°C, measured with the races LOBISONG fits to every DC fan. Field returns agree: cabinets that ran the DC fan at a steady 12V for five years came back clean, and most early failures had been wired backwards. Held at 3,000 RPM, the DC fan lives below its ceiling, so acoustics stay civil.

Where this DC fan earns its place most often:
Wherever a small enclosure traps heat, an 80mm DC fan remains the least expensive cure. LOBISONG stocks all three voltage builds, ships samples, and welcomes buyers who want the DC fan tested on their own bench before the first order.


Procurement teams buy this DC fan for reasons that outlast the invoice: one part number replaces three, the ball bearing build stretches replacement intervals to match the warranty, and a 25mm frame packs more units per carton. LOBISONG builds the DC fan in house, so a buyer may request a marked sample, a speed-versus-current plot or a run-in unit first. Lead lengths, private labelling and kitted packaging for the DC fan are open to OEM programmes.
Can the LB8025 run at 45°C ambient without de-rating?
It can. The ball bearing build serves continuously at that temperature, and the DC fan holds its speed window as cabinet air warms.
Which build should a specifier order, sleeve or ball?
Panels that run all year take the ball version; the sleeve build suits benchtop gear logging a few hundred hours, where the DC fan costs less.
Is the DC fan easy to replace in the field?
Yes. The standard footprint, 2-wire lead and holes let a technician swap the DC fan in minutes, and the DC fan needs no controller.

When heat buildup threatens the performance and lifespan of your equipment, the LOBISONG LB8025 DC Axial Fan delivers the dependable cooling you need. Built in the industry-standard 80 × 80 × 25 mm frame size, this brushless DC fan combines compact dimensions with serious airflow capacity, making it an ideal thermal management solution for enclosures where space is limited but performance cannot be compromised.