Lobisong LBAA2E185S-7MNW-01 AC Axial Fan Ø185 mm

The Lobisong LBAA2E185S-7MNW-01 is a Ø185 mm AC axial fan engineered for reliable fixed-speed ventilation and heat dissipation in demanding industrial environments. 

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

Not every ventilation job has a three-phase power drop. For workshops, warehouses, and retrofit sites where only 220/230V mains is available, the Lobisong LBAA2E185S-7MNW-01 is a plug-and-play 185mm AC axial fan that needs no electrician, no phase converter, no new wiring run. Rated for 220/230V single-phase at 50Hz and spinning at 2400 RPM, this single-phase axial fan moves 670 m³/h—enough to ventilate a mid-size workshop, a warehouse aisle, or a commercial kitchen hood. At 51 dB(A) and IP54 protected, this IP54 ventilation fan combines high air delivery with everyday robustness.

image.pngimage.png

Detailed Product Description & Technical Deep Dive

Why single-phase? Because most small businesses, warehouses, and retrofit locations are wired for 220/230V wall power, not industrial three-phase. A workshop exhaust fan that demands 380V turns a simple replacement into a rewiring project. This 185mm axial fan avoids that: its winding accepts 220/230V across a 198–242V tolerance, so voltage sags from a starting compressor or dimmer will not stall it. A cold-rolled sheet impeller, balanced to G6.3 per JB/T8689, displaces 670 m³/h at a moderate 2400 RPM. The larger 185mm disc means it does not need to spin as fast as a smaller fan to move the same volume—which is why noise stays at 51 dB(A) rather than climbing into the uncomfortable range.


The mechanical build is tuned for hands-off operation. Class F insulation (155°C) and S1 continuous duty let this 185mm axial fan run around the clock, from a factory floor that never stops to a kitchen hood through every lunch service. IP54 keeps workshop dust and cooking grease spray out of the motor, while maintenance-free ball bearings with 30,000-hour L10 life mean this single-phase axial fan never enters the maintenance schedule. Operating across -30°C to +60°C, a winter warehouse or a summer workshop will not push this IP54 ventilation fan beyond rating.
image.png

Key Features & Benefits
  • True single-phase 220/230V operation: No three-phase wiring, no phase converter—this 185mm axial fan plugs straight into standard mains (198–242V tolerance).
  • 670 m³/h AC fan: The 185mm impeller at 2400 RPM moves substantial volume for workshops, warehouses, and kitchen exhausts without an oversized frame.
  • 51 dB(A) moderate noise: Larger swept area moves air at lower perceived noise than a small, fast-spinning alternative—quiet for occupied workrooms.
  • IP54 dust- and spray-resistant: Protects this IP54 ventilation fan against workshop dust, kitchen grease mist, and light outdoor exposure.
  • G6.3 balance per JB/T8689: Vibration is controlled across the larger 185mm diameter, reducing bearing wear and cabinet rattle.
  • S1 continuous duty, 30,000h L10: Sealed bearings and Class F insulation support non-stop operation for years without lubrication or capacitor service.
Technical Specifications Table

Parameter

Value

Model

LBAA2E185S-7MNW-01

Series

LWAA2E185

Motor Type

AC, 1-phase

Voltage

220/230V (range 198~242V)

Frequency

50Hz

Current

0.28 A

Power

55 W

Speed

2400 RPM

Max Airflow

670 m³/h

Noise

51 dB(A)

Ambient Temperature

-30°C ~ +60°C

Storage Temperature

-40°C ~ +80°C

Humidity

0~95% RH

Altitude

< 1000 m

Impeller

Ø185mm cold-rolled sheet

Protection Rating

IP54

Insulation Class

Class F

Bearing

Maintenance-free ball bearings

Duty

S1

Balance Grade

G6.3

Vibration Standard

JB/T8689

Bearing Life

30,000 h (L10)

 

Engineering Advantages & Professional Analysis

The physics behind this 185mm axial fan's easy operation come down to disc area. Airflow scales with swept area times tip speed. A 145mm impeller must spin much faster to move the same volume as a 185mm impeller—and faster tip speed drives noise. This workshop exhaust fan uses the larger 185mm disc to deliver 670 m³/h at a relaxed 2400 RPM, keeping 51 dB(A) within comfort for occupied spaces. For a retrofit contractor, mount this 185mm axial fan in a workshop where people work eight hours a day without triggering hearing-protection requirements.


Single-phase design also simplifies procurement. A maintenance manager replacing a failed exhaust fan does not need to know whether the building has three-phase—this 185mm axial fan works on whatever is on the wall. That removes the most common retrofit delay: "we measured the fan, but the circuit is 220V single-phase." The 55W draw runs from a standard branch circuit, and IP54 tolerates damp, dusty warehouses. For SMB buyers, plug-and-play wiring and 30,000-hour bearing life mean this 185mm axial fan is installed once and forgotten.

Target Applications
  • Workshop and factory ventilation: Use this workshop exhaust fan to purge welding fumes, grinding dust, and process heat from mid-size workshop floors.
  • Warehouse and storage ventilation: 670 m³/h AC fan exchanges air in warehouse aisles and storage rooms where three-phase power is unavailable.
  • Commercial kitchen exhaust: IP54 protection and single-phase supply suit hood and make-up-air duties in restaurants and food-prep kitchens.
  • Small HVAC and makeup-air units: Integrate this 185mm axial fan into rooftop makeup-air handlers and small ducted exhaust systems.
  • Retrofit and replacement projects: Drop the single-phase axial fan into existing exhaust cabinets where the old unit was wired for 220/230V mains.
Commercial Value & B2B ROI

For contractors and SMB buyers, industrial fan ROI is simplicity. No need to inventory both single-phase and three-phase variants—this workshop exhaust fan runs on the power every workshop already has. The 55W draw boosts industrial fan ROI, and 30,000-hour L10 bearing life means the fan typically outlasts the equipment it serves. Because installation requires only a standard 220/230V connection, an electrician is not needed for most replacements. For distributors, stocking this single-phase axial fan model covers the bulk of retrofit and SMB ventilation enquiries—industrial fan ROI.

image(e38a001587).pngimage.png

Frequently Asked Questions (FAQ)

Q1: Can this 185mm axial fan be hard-wired to a 220V branch circuit?

A: Yes. It is rated for 220/230V single-phase with 198–242V tolerance. Hard-wiring to a standard branch circuit is typical; the 0.28A / 55W draw fits ordinary circuit protection. No three-phase supply is required beyond what is internal to the motor.

Q2: How much static pressure can this single-phase axial fan overcome?

A: 670 m³/h AC fan is low-to-medium pressure design for open grille, light ducted exhaust, and filter-backed cabinet applications. It moves 670 m³/h through a short low-loss duct run, but is not a substitute for a high-static-pressure centrifugal fan on heavily filtered systems. If duct resistance exceeds ~100 Pa, consider a centrifugal alternative.

Q3: Is this IP54 ventilation fan suitable for a commercial kitchen?

A: Yes—IP54 resists grease spray and kitchen dust, and single-phase supply matches typical restaurant power. It is not rated for pressure wash-down or direct water jets; schedule periodic impeller cleaning if heavy grease accumulates, and use a grease-rated filter upstream to protect airflow.

image(c13e1c5178).pngimage(ca40dcda6d).png

Lobisong LBAA2E185S-7MNW-01 AC Axial Fan Ø185 mm

The Lobisong LBAA2E185S-7MNW-01 is a Ø185 mm AC axial fan engineered for reliable fixed-speed ventilation and heat dissipation in demanding industrial environments. 